Table 5. Troubleshooting (continued)

Problem

 

 

 

indicator

Component

Possible cause

Possible solutions

 

 

 

 

Hard disk drive is

Several

Drive failure

Replace the failed drive or drives.

not visible in the

components

 

 

SAS cable failed

Replace the SAS cable.

Storage Manager

 

 

 

 

 

RAID controller

Replace RAID controller.

software

 

 

 

failure

 

 

 

 

 

 

 

Midplane failure

Replace the DS3200. Contact

 

 

 

your IBM technical-support

 

 

 

representative.

 

 

 

 

 

 

A drive has an

Replace the drive.

 

 

interface problem

 

 

 

with the ESM or

 

 

 

controller.

 

 

 

 

 

 

 

Incorrect firmware

Make sure that the DS3200 has

 

 

version

the correct firmware version. See

 

 

 

“Software and hardware

 

 

 

compatibility and upgrades” on

 

 

 

page 11.

 

 

 

 

 

 

In a dual-controller

Replace the failed controller and

 

 

storage subsystem,

ESM.

 

 

one controller has

 

 

 

failed, and in the

 

 

 

drive channel that

 

 

 

originates from the

 

 

 

other (functioning)

 

 

 

controller, an ESM

 

 

 

has failed.

 

 

 

 

 

Chapter 6. Solving problems 103

Page 121
Image 121