Features and operating specifications
Table 1 contains a summary of the features and operating specifications of the DS3200. Depending on your DS3200 model, some features might not be available, or some specifications might not apply.
Table 1. Features and operating specifications
General:
vModular components
–
–RAID controller modules
–Power supplies with
vTechnology
–Supports disk array technology
–SAS host interface, redundant data storage, power and cooling system, and SAS and SATA disk controllers
–
vUser interface
–
–
Hard disk drive storage:
Maximum hard disk drives per DS3200: 12
Drive type: SAS and SATA
Controllers:
vTechnology and interfaces:
SAS interface: Two
Acoustical noise emissions:
For maximum system configurations (12 hard disk drives installed)
vSound power (idling): 6.2 bels
vSound power (operating): 6.2 bels
vSound pressure (idling): 48 dBA
vSound pressure (operating): 48 dBA
AC power supply with built-in fan:
vThe DS3200 comes with two
vThe two power supplies provide redundant power to the DS3200.
Size:
vHeight: 8.7 cm (3.4 in.)
vDepth: 55.0 cm (21.6 in.)
vWidth: 44.7 cm (17.6 in.)
vWeight: approximately 17.1 kg (37.6 lb) for a standard unit; when fully configured, 29.3 kg
(64.6 lb)
Environment:
vAir temperature:
–DS3200 on: 10° to 35°C (50.0°
to 95°F); altitude: 30.5 (100 ft) below to 3000 m (9840 ft) above sea level; temperature change: 10°C (18°F) per hour
–DS3200 off: 10° to 50°C (14.0° to 120.0°F); maximum altitude: 3000 m (9840 ft); temperature change: 15°C (27.0°F) per hour
vHumidity:
–DS3200 on: 20% to 80%
–DS3200 off: 10% to 90%
–Maximum dew point: 26°C (79°F)
–Maximum humidity gradient: 10% per hour
Heat output
Approximate heat output in British thermal units (Btu) per hour:
vMinimum configuration: 205 Btu (60 watts)
vMaximum configuration 1235 Btu (361 watts)
Electrical input:
v
vInput voltage low range:
–Minimum: 90 V ac
–Maximum: 136 V ac
vInput voltage high range:
–Minimum: 198 V ac
–Maximum: 264 V ac
vApproximate input
–Minimum: 0.06 kVA
–Maximum: 0.38 kVA
Notes:
1.Power consumption and heat output vary depending on the number and type of optional features that are installed and the
2.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual
4System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide