Features and operating specifications

Table 1 contains a summary of the features and operating specifications of the DS3200. Depending on your DS3200 model, some features might not be available, or some specifications might not apply.

Table 1. Features and operating specifications

General:

vModular components

High-capacity disk drives

RAID controller modules

Power supplies with built-in fan units

vTechnology

Supports disk array technology

SAS host interface, redundant data storage, power and cooling system, and SAS and SATA disk controllers

Hot-swap technology for hard disk drives, power supplies, and controllers

vUser interface

Built-in power, activity, and fault LEDs, identification labeling on components, rear LEDs, and connectors

Easy-to-replace hard disk drives, power supplies with built-in fan units, and controllers

Hard disk drive storage:

Maximum hard disk drives per DS3200: 12

Drive type: SAS and SATA

Controllers:

vTechnology and interfaces:

SAS interface: Two 26-pin, mini-SAS connectors per controller (two more with optional SAS host port adapter installed)

Acoustical noise emissions:

For maximum system configurations (12 hard disk drives installed)

vSound power (idling): 6.2 bels

vSound power (operating): 6.2 bels

vSound pressure (idling): 48 dBA

vSound pressure (operating): 48 dBA

AC power supply with built-in fan:

vThe DS3200 comes with two hot-swap 530-watt (115 - 230 V ac) power supplies.

vThe two power supplies provide redundant power to the DS3200.

Size:

vHeight: 8.7 cm (3.4 in.)

vDepth: 55.0 cm (21.6 in.)

vWidth: 44.7 cm (17.6 in.)

vWeight: approximately 17.1 kg (37.6 lb) for a standard unit; when fully configured, 29.3 kg

(64.6 lb)

Environment:

vAir temperature:

DS3200 on: 10° to 35°C (50.0°

to 95°F); altitude: 30.5 (100 ft) below to 3000 m (9840 ft) above sea level; temperature change: 10°C (18°F) per hour

DS3200 off: 10° to 50°C (14.0° to 120.0°F); maximum altitude: 3000 m (9840 ft); temperature change: 15°C (27.0°F) per hour

vHumidity:

DS3200 on: 20% to 80%

DS3200 off: 10% to 90%

Maximum dew point: 26°C (79°F)

Maximum humidity gradient: 10% per hour

Heat output

Approximate heat output in British thermal units (Btu) per hour:

vMinimum configuration: 205 Btu (60 watts)

vMaximum configuration 1235 Btu (361 watts)

Electrical input:

vSine-wave input (50 - 60 Hz) required

vInput voltage low range:

Minimum: 90 V ac

Maximum: 136 V ac

vInput voltage high range:

Minimum: 198 V ac

Maximum: 264 V ac

vApproximate input kilovolt-amperes (kVA):

Minimum: 0.06 kVA

Maximum: 0.38 kVA

Notes:

1.Power consumption and heat output vary depending on the number and type of optional features that are installed and the power-management optional features that are in use.

2.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average stated values because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.

4System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Page 22
Image 22