Integra RDC-7.1 Terminal – Other than USA and Canadian models, A 200 mA, B, C, D and E 100 mA

Models: RDC-7.1

1 156
Download 156 pages 25.69 Kb
Page 49
Image 49
Using an External Device with 12V Trigger

If Remote Controller Signal Does not Reach Other Components

Effective Sensor Layout

In this situation, you will need to use a commercially available IR emitter. Connect the mini plug of the IR emitter to the IR OUT terminal on the RDC-7.1 and then place the IR emitter on the remote sensor of the component or facing it. When the IR emitter is con- nected, only the signal input to the IR IN terminal is output to the IR OUT terminal. The signal input from the remote sensor on the front of the RDC-7.1 will not be output to the IR OUT terminal.

Connecting

IR Receiver

 

block

 

IR IN

 

RDC-7.1

 

IR OUT

 

IR Emitter

 

Remote controller

Other

 

component

 

 

: Signal flow

Making Sensor Connections

When you place the IR receiver in the main room, con- nect the cable from the connecting block to the IR OUT MAIN terminal. When you place the IR receiver in the remote zone, connect the cable from the connecting

Using an External Device with 12V Trigger

Terminal – Other than USA and

Canadian models –

You can automatically turn on the connected AV com- ponents with the output signal from the RDC-7.1’s 12V TRIGGER OUT terminal.

Making a Connection

Connect the 12V TRIGGER OUT terminal on the RDC-7.1 to the 12V TRIGGER IN terminal on other components. Every 12V TRIGGER OUT terminal can be connected to the components whether they are placed in the main room, Zone 2, or Zone 3.

The RDC-7.1 has five 12V TRIGGER OUT terminals and the maximum currents to be connected are as fol- lows:

A: 200 mA

 

andInstallationConnections

Device A

12V TRIGGER

B, C, D and E: 100 mA

 

After making connections, configure the association between the room (zone) and the component to be turned on (Refer to “12V Trigger Assign” under “Input Setup” on page 102).

IN

200mA MAX.

 

12V

 

TRIGGER

 

OUT

 

A

Device B

200mA MAX.

B 100mA MAX.

12V TRIGGER

IN

C

block to the ZONE 2 or ZONE 3 terminal accordingly.

100mA MAX.

100mA MAX.

Other component

 

: Signal flow

Remote control

 

 

 

 

sensor

 

Mini plug

Emitter

 

 

MAIN

IR Emitter

 

ZONE 2

ZONE 3

D 100mA MAX.

E

100mA MAX.

Device C

12V TRIGGER

 

IN

 

100mA MAX.

Device D

12V TRIGGER

IN Terminal – Other than USA andA: 200 mA OUT

IR

RDC-7.1

Device E

IN

100mA MAX.

12V TRIGGER

IN

100mA MAX.

49

Page 49
Image 49
Integra RDC-7.1 Terminal – Other than USA and Canadian models, A 200 mA, B, C, D and E 100 mA, Effective Sensor Layout