MultiProcessor Specification
3.6.3Assignment of System Interrupts to the APIC Local Unit
The APIC local unit has two general-purpose interrupt inputs, which are reserved for system interrupts. These interrupt inputs can be individually programmed to different operating modes. Like the I/O APIC interrupt lines, the local APIC interrupt line assignments of a non-PC/AT- compatible system are system implementation specific. Refer to Chapter 4 for custom implementations and to Chapter 5 for default configurations.
3.6.4Floating Point Exception Interrupt
For PC/AT compatibility, the bootstrap processor must support DOS-compatible FPU execution and exception handling while running in either of the PC/AT-compatible modes. This means that floating point error signals from the BSP must be routed to the interrupt request 13 signal, IRQ13, when the system is in PIC or virtual wire mode. While floating point error signals from an application processor need not be routed to IRQ13, platform designers may choose to connect the two. For example, connecting the floating point error signal from application processors to IRQ13 can be useful in the case of a platform that supports dynamic choice of BSP during boot.
In symmetric mode, a compliant system supports only on-chip floating point units, with error signaling via interrupt vector 16. Operating systems must use interrupt vector 16 to manage floating point exceptions when the system is in symmetric mode.
It is recommended that hardware platforms be designed to block delivery of floating point exception signals from the processors once the system has switched into symmetric mode to avoid delivery of superfluous interrupts. If done, such blocking must be implemented in a manner that is transparent to the operating system. However, the operating system must still be prepared to handle interrupts generated through assertion of floating point error signals, because on some platforms these signals may still be routed to IRQ13 even after the switch to symmetric mode.
3.6.5APIC Memory Mapping
In a compliant system, all APICs must be implemented as memory-mapped I/O devices. APIC base addresses are at the top of the memory address space. All APIC local units are mapped to the same addresses, which are not shared. Each processor accesses its local APIC via these memory addresses. The default base address for the local APICs is 0FEE0_0000h.
Unlike the local APICs, the I/O APICs are mapped to give shared access from all processors, providing full symmetric I/O access. The default base address for the first I/O APIC is 0FEC0_0000h. Subsequent I/O APIC addresses are assigned in 4K increments. For example, the second I/O APIC is at 0FEC0_1000h.
Non-default APIC base addresses can be used if the MP configuration table is provided. (Refer to Chapter 4.) However, the local APIC base address must be aligned on a 4K boundary, and the I/O APIC base address must be aligned on a 1K boundary.