Intel MultiProcessor manual B.5 APShutdown Handling, B.4.2 USINGSTARTUP IPI

Models: MultiProcessor

1 97
Download 97 pages 61.7 Kb
Page 79
Image 79
B.4.2 USING STARTUP IPI

Operating System Programming Guidelines

By putting an appropriate pointer in the warm-reset vector, setting the shutdown code to 0Ah, then causing an INIT, the BIOS (or the operating system) can cause the current processor to jump immediately to any location. Because all processors in an MP system share the same system memory, and because the INIT IPI gives one processor the power to cause an INIT at another, the operating system can cause any processor to jump immediately to any location.

B.4.2 USING STARTUP IPI

STARTUP IPIs are used with systems based on Intel processors with local APIC versions of 1.x or higher. These local APICs recognize the STARTUP IPI, which is an APIC Interprocessor Interrupt with trigger mode set to edge and delivery mode set to “110” (bits 8 through 10 of the ICR).

The STARTUP IPI causes the target processor to start executing in Real Mode from address 000VV000h, where VV is an 8-bit vector that is part of the IPI message. Startup vectors are limited to a 4-kilobyte page boundary in the first megabyte of the address space. Vectors A0-BF are reserved; do not use vectors in this range. STARTUP IPIs are not maskable, do not cause any change of state in the target processor (except for the change to the instruction pointer), and can be issued only one time after RESET or after an INIT IPI reception or pin assertion. A STARTUP IPI neither requires the targeted APIC to be enabled nor the interrupt table to be programmed. If the target processor is in the halted state immediately after RESET or INIT, a STARTUP IPI causes it to leave that state and start executing. The effect is to set CS:IP to VV00:0000h.

For an operating system to use a STARTUP IPI to wake up an AP, the address of the AP initialization routine (or of a branch to that routine) must be in the form of 000VV000h. Sending a STARTUP IPI with VV as its vector causes the AP to jump immediately to and begin executing the operating system’s AP initialization routine.

The operating system should not issue a STARTUP IPI to an 82489DX since the STARTUP IPI will be ignored instead of forcing the targeted processor to execute from the given address.

B.5 AP Shutdown Handling

An AP may be shut down by itself, by the BSP, or by another active AP. Shutting down an AP with an active task or a bound device driver is not permitted. Only the BSP may shut itself down, and it must be the last processor to shut down.

There are several possible alternatives for shutdown handling. Two of the possibilities are presented here by way of example.

In the simplest case, the operating system can define an IPI for shutting down and taking APs off- line. The exact usage and behavior of an IPI that is defined for this purpose is operating system specific and is not defined in this specification.

Should the BSP need to take an AP off-line or to place the AP back into a HALT state, the BSP can also use the INIT IPI with Warm Restart. The operating system places the address of a HLT instruction in the warm-reset vector (40:67), sets the CMOS shut-down code to 0Ah, then sends an INIT IPI to the AP. The INIT IPI causes the AP to enter the BIOS POST routine, where it immediately jumps to the warm-reset vector and executes the operating system’s HLT instruction. Only one processor can execute the shutdown routine at any given time, due to the use of the shutdown code. The operating system must not rely on any code being executed after the delivery

Version 1.4

B-5

Page 79
Image 79
Intel MultiProcessor manual B.5 APShutdown Handling, B.4.2 USINGSTARTUP IPI