Hardware Management
If you have selected an American switch type, you can edit CSU properties for the board. DS1 is the long haul configuration used for connecting the board to a T1/PRI line. If the board is connected directly to the line in a standard DS1 configuration, the board’s internal CSU must be activated for each PRI port. (For more information about line connections, see T1/PRI Line on page 27.)
The following table describes DS1 options that can be edited:
Option | Description | |
|
| |
Activate the | A direct DS1 connection between the board and the | |
CSU | network’s T1/PRI line requires a CSU. | |
| • Select Activate the CSU to activate the board’s | |
|
| internal CSU for the port. |
| • Deselect Activate the CSU to deactivate the board’s | |
|
| internal CSU for the port. |
| The CSU facility is protected by a password. You must | |
| enter the password the first time you select Activate the | |
| CSU. | |
|
| |
Network Line | The Network line build out compensates for the signal | |
Build Out | attenuation due to the length of the cable between the | |
| board and the switch. | |
| Four values are available (expressed in dB): | |
| • | 0 |
| • | 7.5 |
| • | 15 |
| • | 22.5. |
| Select the value indicated by your Telco. If this | |
| information is not available, use 0 dB. |
84 | Interphase Corporation |