Setting Up Call Properties
Field | Description |
|
|
Local | Enter the local subscriber number(s) for a port to route an |
Subscriber | incoming call to that port when several ports are able to |
Number | accept the call. The local subscriber number(s) must match |
| the subscription number(s) your local Telco has assigned to |
| your line. |
| This field is available only at the port level. If multiple types |
| of ports accept the same channel type, it is required for each |
| affected port. Otherwise, it is optional. Ports of the same |
| type, such as COM ports, can use the same local subscriber |
| number(s). |
| NOTE: On a |
| the ISDN RAS port only if the ISDN physical line supports |
| Multiple Subscriber Numbers (MSN). |
|
|
Modem | Use the Modem Initialization Strings field to enter |
Initialization | initialization strings for incoming and outgoing calls, if |
Strings | needed. |
(Hayes | This field is available only for the DM RAS modem port and |
Commands) | for DM serial driver COM ports. It is optional. |
|
|
You can select multiple ports of the same type in the tree view (that is, multiple ISDN or COM ports) and configure them together.
The way incoming calls are routed depends on the Channel type values selected and the Local subscriber numbers entered.