Problems and Possible Solutions
Problem | Possible Solution(s) | |
|
|
|
LoopTest failed | 1. | Check the cable connection between the board and |
|
| the ISDN network. |
| 2. | Make sure the ISDN switch type configured for the |
|
| board matches the switch the board is using. |
| 3. | Check the phone number. |
| 4. | For more detailed information, see Understanding |
|
| |
|
| |
ISDN RAS Dial- | The following possible solutions assume a successful | |
out failed | LoopTest. (If you do not know how to access the | |
| Remote Access Setup dialog box or otherwise check | |
| the following items, see Index of Common Tasks on | |
| page 177.) | |
| 1. | Make sure at least one ISDN RAS port is configured |
|
| to make outgoing calls. (On the Remote Access |
|
| Setup dialog box, select a port and click |
|
| Configure.) |
| 2. | Make sure the protocol(s) used by the remote user |
|
| (IP, IPX/SPX, or NetBEUI) are configured in RAS |
|
| |
|
| dialog box, click Network.) |
| 3. | Check your user ID and password. |
| 4. | Use SynWatch to see if an ISDN connection |
|
| problem exists. See Using the SynWatch Utility on |
|
| |
| 5. | Use SynWatch to see if a PPP negotiation problem |
|
| exists. |
124 | Interphase Corporation |