2Enter Disk mode, and touch the LCD screen to make the TRITON STUDIO detect the disk.

8Press the OK button to load the data.

Never remove the media while data is being loaded.

3Press the Load tab to access the Load page. The LCD screen will display file information.

4Use “Drive select” to select the FDD.

5Select the PRELOAD.PCG file. The selected file will be highlighted.

6Select the page menu command “Load Selected.”

A dialog box will appear.

The contents and settings of the dialog box will differ depending on the type of file that you are loading.

7In “.PCG Contents,” specify the data that you want to load.

If you want to load all data from the .PCG file, select All.

Since in this example we want to restore all settings to the factory-set condition, we will select All. If you load PRELOAD.PCG from the included floppy disk with All selected, all data of the .PCG file will be loaded as follows.

Programs

Bank I-A file: loaded into bank INT-A

Bank I-B file: loaded into bank INT-B

Bank I-C file: loaded into bank INT-C

Bank I-D file: loaded into bank INT-D

Bank I-E file: loaded into bank INT-E

Combinations

Bank I-A file: loaded into bank INT-A

Bank I-B file: loaded into bank INT-B

Bank I-C file: loaded into bank INT-C

Bank I-D file: loaded into bank INT-D

Drum Kits

000–015 (I-A/B) file: loaded into bank I-A/B

128–143 (User) file: loaded into bank User

Arpeggio Patterns

000–199 (I-A/B) file: loaded into bank I-A/B

312–506 (User) file: loaded into bank User

Loading individual banks from a .PCG file

In the dialog box for step 6 of “Loading data/Restoring the factory settings,” it is also possible to set “.PCG Con- tents” to specify an individual bank to load, and set the “To” field to select the bank into which that data will be loaded.

When you execute loading, only the programs, combina- tions, drum kits, and user arpeggio pattern data of the selected bank will be loaded into the load-destination bank you specify. Global setting data will not be loaded.

If you set “.PCG Contents” to Bank I-A, and “To” to Bank I-A, data will be loaded as follows.

Programs

• Bank I-A file: loaded into bank INT-A

Combinations

• Bank I-A file: loaded into bank INT-A

Drum Kits

00–15 (I-A/B) file: loaded into bank I-A/B

Arpeggio Patterns

000–199 (I-A/B) file: loaded into bank I-A/B

When data is loaded into a bank that is different than its original bank, the data (bank, program, pattern, and kit numbers, etc.) will automatically be reconfigured so that after loading, the various types of data will corre- spond correctly in each mode.

The following data will also be reconfigured automati- cally if you have checked “Load .SNG too” (so that song data is loaded at the same time), in order to ensure that the song data plays back correctly.

The bank of each program used by combinations

The pattern number of each user arpeggio pattern used by the combinations/programs/songs

The kit number of the drum kit used by each program

The bank of the program used by each track of the song

If the song contains track/pattern events, the program banks within these events