11: Monitor

Configuration

Configure the monitoring of a connected serial device through specific configuration settings pages : Initialization, Control, Poll , Filter, and Data. Access the configuration options displayed in Table 11-2on the Initialization page. These configuration fields are the same ones in Step 1: Setup Initiation if utilizing Explorer.

 

Table 11-2 Monitor Initialization Settings

 

 

Initialization

Description

Settings

 

Initial Delay

Set the initial delay time in milliseconds before the monitor starts processing the

 

initialization message. This field also appears in Step 1: Setup Initiation.

 

 

Message <Number>

Click the Edit link to edit a specific message; this is where a command is entered.

 

Four message fields will open to allow configuration of a specific command. When

Note: In other pages

you begin entering information in these fields, additional Message <Number>

options become available containing the four message fields which will also open

(Commands/Control

upon clicking Edit. Complete the Message <Number> fields:

and Poll) in Explorer

Command: enter the command in binary format (printable characters or binary

or under

string)

Configuration,

End Character: indicate as a single printable character or as a control character.

additional Message

Control characters may be input as <control>J, 0xA (hexadecimal) or \10

<Number> fields will

(decimal).

become available to

Length: set the length of the response.

further filter and

Timeout: set the timeout length. Minimum timeout length is 100 milliseconds.

specify the information

you wish to monitor.

Click Submit after making changes to get real time response displayed if you are

 

utilizing Explorer.

 

 

Access the configuration options displayed in Table 11-3on the Control page. These configuration fields are the same ones in Step 2: Setup Commands if utilizing Explorer.

 

Table 11-3 Monitor Control Settings

 

 

Control Settings

Description

Message <Number>

Click the Edit link to edit a specific message; this is where a command is entered.

 

Four message fields will open to allow configuration of a specific command. When

Note: In other pages

you begin entering information in these fields, additional Message <Number>

options become available containing the four message fields which will also open

(Commands/Control

upon clicking Edit. Complete the Message <Number> fields:

and Poll) in Explorer

Command: enter the command in binary format (printable characters or binary

or under

string)

Configuration,

End Character: indicate as a single printable character or as a control character.

additional Message

Control characters may be input as <control>J, 0xA (hexadecimal)

<Number> fields will

or \10 (decimal).

become available to

Length: set the length of the response.

further filter and

specify the information

Timeout: set the timeout length. Minimum timeout length is 100 milliseconds.

you wish to monitor.

Click Submit after making changes to get real time response displayed if you are

 

utilizing Explorer.

 

 