6: Tunnel Settings

Tunnel Accept Mode

Description

Settings (continued)

 

Flush Start Character

Enable or disable the flush start character:

 

Enabled = prevents forwarding of a start character from the Line into

 

the network.

 

Disabled = the flush start character allows forwarding of a start

 

character from the line into the network.

 

Note: This configuration option becomes available when Start Character

 

is the selected Mode.

 

 

Flush Line

Set whether the serial line data buffer is flushed upon a new network

 

connection. Choices are:

 

Enabled = serial data buffer is flushed on network connection

 

Disabled = serial data buffer is not flushed on network connection

 

(default)

 

 

Block Line

Set whether Block Line is enabled for debugging purposes. Choices are:

 

Enabled = if Enabled, incoming characters from the serial line will not

 

be forwarded to the network. Instead, they will be buffered and will

 

eventually flow off the serial line if hardware or software flow control is

 

configured.

 

Disabled = this is the default setting; incoming characters from the

 

Serial Line are sent into the network. Any buffered characters are sent

 

first.

 

 

Block Network

Set whether Block Network is enabled for debugging purposes. Choices

 

are:

 

Enabled = if Enabled, incoming characters from the network will not be

 

forwarded to the Serial Line. Instead, they will be buffered and will

 

eventually flow off the network side.

 

Disabled = this is the default setting; incoming characters from the

 

network are sent on the Serial Line. Any buffered characters are sent

 

first.

 

 

Password

Enter a password. This password can be up to 31 characters in length and

 

must contain only alphanumeric characters and punctuation. When set,

 

clients must send the correct password string to the unit within 30 seconds

 

from opening network connection in order to enable data transmission.

 

The password sent to the unit must be terminated with one of the following:

 

0A (Line Feed)

 

00 (Null)

 

0D 0A (Carriage Return/Line Feed)

 

0D 00 (Carriage Return/Null)

 

If, Prompt for Password is set to Enabled and a password is provided,

 

the user will be prompted for the password upon connection.

 

 

To Configure Tunnel Accept Mode Settings

Using Web Manager

To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Accept.

Using CLI

To enter the Tunnel command level: config -> Tunnel <instance>

xPico® Wi-Fi® Embedded Device Server User Guide

37

Page 37
Image 37
Lantronix 900-691-R manual To Configure Tunnel Accept Mode Settings