Appendix A: Command Reference

configgroup Monitor Data

These settings pertain to Monitor Data in the device.

Data configured here will be accessible through the status of Monitor.

configitem Selector

value Name

Sets Name to enable the data selector.

Name may contain up to 16 characters.

value Response

Sets Response instance to select the source of data. Response instance corresponds to Poll or Control Message instance.

Blank the value for "<None>".

value Reference

Sets the Reference in dot number format.

Reference selects the output of Monitor Filter. E.g. If data should select the second trunk of data created by filter 1, Reference must be set to "1.2". A Reference of "0" indicates the raw response.

Dot number format could be "0" or two numbers separated by a dot (e.g. "1.2"). Reference may contain up to 6 characters.

configgroup Tunnel Accept

Tunnel Accept Mode controls how a tunnel behaves when a connection attempt originates from the network.

configitem Mode

value

An Accept Tunnel can be started in a number of ways, according to its Mode: Disabled: never started.

Always: always started.

Any Character: started when any character is read on the Serial Line.

Start Character: started when the Start Character is read on the Serial Line.

Modem Control Asserted: started when the Modem Control pin is asserted on the Serial Line.

Mode may be "Disable", "Always", "Any Character", "Start Character" or "Modem Control Asserted".

configitem Local Port

value

The Local Port value can be overridden. By default, it is 10001 for Tunnel 1, 10002 for Tunnel 2, and so on.

Blank the display field to restore the default.

xPico® Wi-Fi® Embedded Device Server User Guide

92