Lantronix SLSLP400PS201 manual

Models: SLSLP400PS201

1 133
Download 133 pages 49.58 Kb
Page 32
Image 32

3: Installing the Spider Device

Perform the following steps to configure the mouse-to-cursor synchronization.

Windows Server

1.Select Control Panel > Mouse > Pointer Options.

2.Set the pointer speed to medium and disable Enhanced pointer precision.

Linux Server

1.Set Mouse Acceleration to exactly 1 and threshold to exactly 1.

2.Select Other Operating Systems on the Spider mouse settings page.

Solaris Server

1.Set the mouse settings by using the CDE control panel to “1:1, no acceleration” or “xset m 1”.

Mac OS X Server

1. Set the Spider device to Single Mouse Mode.

Telnet/SSH Connections to Serial Ports

To Telnet/SSH to a target computer serial port, you must Telnet/SSH to the Spider serial port first and use connect serial CLI. This connects your Spider device to the target computer serial port. The default settings are 9600 bps, 8 data bits, 1 stop bit, no parity, and no flow control. The pinout of the included Spider cables match a standard DB9 COM port.

Cable Connections for KVM and USB

Connections for KVM and USB are integrated into the Spider device. Do not use extension cables. Plug the Spider device directly into the ports on the host server. If using the Spider serial port, plug the cable into the COM port on the server.

The second Cascade Ethernet port can connect to the Spider device to the target computer management LAN port, or to a main LAN port, or to a Spider device chain. When connecting the Ethernet ports, straight through or crossover cables can be used, because the Spider device has auto-polarity and auto-crossover correction. Although the port marked Ethernet and the port marked Cascade are both Ethernet interfaces, you must use the port marked Ethernet if using only one Ethernet interface.

Perform the following steps when daisy chaining Spider devices.

1.Plug the outside network cable into the left Ethernet port of the first Spider device.

2.Connect the right Cascade port to the left port of the next Spider device in the chain.

3.Repeat as necessary. The last Spider device in the chain should have its right port unoccupied, unless cabling in a loop for redundant connection.

Device Failure or Cable Break in the Daisy Chain

If a device fails or there is a cable break in the daisy chain, there could be a loss of network connectivity for all devices downstream from the cable break or device failure. Avert this issue by installing Spanning Tree in the switch or router to which the Spider device chain attaches. Then, connect the last Spider device from its Cascade port to the same switch so that there is a redundant outside connection.

Spider™ and SpiderDuo® KVM-over-IP Device User Guide

32

Page 32
Image 32
Lantronix SLSLP400PS201 manual