9: Services

2. Modify the following fields.

 

Table 9-2 Date/Time Settings

 

 

Field

Description

 

 

UTC Offset

Time servers deliver time as Coordinated Universal Time (UTC, or

 

Greenwich Mean Time). Select the appropriate offset in hours ± from the

 

drop-down menu.

User Specified Time

Manually input the current date and time. The Spider device keeps time as

 

long as power is applied. It has an internal calendar, but does not know

 

about daylight savings time and requires resetting twice a year. The internal

 

clock accuracy is ±30 ppm.

 

 

Synchronize with NTP

Enter a primary and secondary time server in the respective fields. Ensure

Server

NAT and firewalls are set up to allow the protocol to pass. Also, provide the

 

Spider device with DNS server names.

3.Do one of the following:

a.Click Save to save settings.

b.Click Reset to Defaults to restore system defaults.

c.Click Reset to restore original settings.

Security

General settings for security parameters such as encryption and access control are at Services > Security. Other areas with security implications include User Management/Permissions, Authentication, Network Settings, and the Event Log; see the appropriate sections for information on those areas.

To modify security settings, perform the following steps.

1.Click Services > Security. The Security page displays.

Spider™ and SpiderDuo® KVM-over-IP Device User Guide