Mitsubishi Electronics DX-TL5000U Alarm in terminals, Alarm OUT terminals, Reset button

Models: DX-TL5000U

1 143
Download 143 pages 49.43 Kb
Page 20
Image 20

Major operations and their functions (continued)

Rear view (continued)

3

4

5 6 7

8

9

10

IN

1

2

3

4

5

6

7

8

OUT

 

 

 

 

 

 

 

 

 

 

 

 

CAMERA

 

 

 

 

IN

9

10

11

12

13

14

15

16

OUT

 

 

 

 

 

 

 

 

 

 

CLAMPER

 

 

 

 

 

 

VIDEO VIDEO

Y/C

OUTPUT A OUTPUT B

CLAMPER

OUT IN

VIDEO CASCADE

SERIAL BUS SERIAL BUS

AUDIO IN

1

2

3

4

OUT

IN

AUDIO

CASCADE

 

AUDIO OUT

LAN-A

LAN-B

OPTION SLOT

AC IN~

MAIN

100-240V

OFF ON

1 2

GND

RS-232C

11 12

ALARM OUT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

13

RESET

ALARM IN

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

14

100

 

 

 

 

 

10 100

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORAGE

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOCKADJ

ADJCLOCKOUT

REC

STOPREC

EMERGENCY

RESERVED

OUTMODE1 +

OUTMODE1—

OUTMODE2 +

OUTMODE2—

OUTMODE3 +

OUTMODE3—

OUTMODE4 +

OUTMODE4—

OUTCALL+

OUTCALL—

350mAMAX 12VDCOUT

 

 

 

 

 

TERMRS485+

TERMRS485—

RS422+ RS422—

RS232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485

RS485

 

 

P T Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 16 17

13.ALARM IN terminals

Input terminals for alarm signal.

ALARM OUT terminals

Output terminals for alarm signal.

14.RESET button

Used to reset the unit and turn off the power. At this time, picture data, menu settings, and the present time are kept.

15.I/O terminals

CLOCK ADJ terminal

Input terminal to set the present time. Time display is adjusted to the nearest hour (00 minutes 00 sec- onds) when this terminal receives the CLOCK ADJ signal.

The on-screen clock is reset to the nearest hour by applying a signal to the CLOCK ADJ terminal. For example, if the current time is 11:29:59, it will be reset to 11:00:00, and if the current time is 11:30:00, it will be reset to 12:00:00.

CLOCK ADJ OUT terminal

Output terminal to send the signal to the other recorders connected for adjusting the clock to the nearest hour (00 minutes 00 seconds).

REC terminal

Input terminal to start recording. This terminal is not available during timer recording.

REC STOP terminal

Input terminal to stop recording. This terminal is not available during timer recording.

EMERGENCY terminal

Input terminal to start EMERGENCY recording im- mediately.

MODE OUT 1 to MODE OUT 4 terminals

Output terminal to indicate the current mode of this unit. Select the mode of the unit to be output in the <Mode Out Settings> (Setup MenuSystemRear Terminal SettingMode Out Settings).

CALL OUT terminals/CALL OUT GND terminal

This is a ISOLATION output terminal. Information to be transmitted externally consists of CALL OUT settings made in the <Call Out Settings> (Setup MenuSystemRear Terminal SettingCall Out Settings) as well as fixed output settings.

DC 12 V OUT terminal

Output the voltage only when both the MAIN switch and POWER button are turned ON. The maximum electric current is 350 mA.

16.RS485 IN/OUT connectors

Connectors for control of cascade recorders. Used to connect with the other recorders.

17.RS422/RS232C connectors

Connectors for connecting PTZ cameras to oper- ate pan, tilt, and zoom functions of the camera.