“Main-Alarm” appears when “Alarm Recording Area” (System MenuMemoryData Management Setting for Main MemoryChange Partition Setting) is set to other than “0 %.”

“Main-LPA” appears when “Long Pre-Alarm Area” (System MenuMemoryData Management Setting for Main MemoryChange Partition Setting) is set to other than “0 %.”

step3. Set the desired capacity.

Set the remaining capacity of each device to output signal.

Call Out Settings

This item is used to output warning signals from the CALL OUT terminal to the device connected when the capacity becomes full or reaches to the specified value.

Setup Menu

4 System

3 Rear Terminal Setting

2 Call Out Settings

step1. Set the desired capacity for each area.

Off: Does not output a signal.

“Alarm Recording Area” can be set when “Alarm Recording Area” (System MenuMemoryData Management Setting for Main MemoryChange Partition Setting) is set to other than “0 %.”

“LPA Recording Area” can be set when “Long Pre- Alarm Area” (System Menu Memory Data Management Setting for Main MemoryChange Partition Setting) is set to other than “0 %.”

Call out settings use the photo-coupler output to decrease the malfunctions due to wiring. See CALL

OUT signal output ( see page 18) for the correct connection.

For the relationship between the warning display and

CALL OUT signal output, see pages 114 and 115. The warning display of the item written “Fixed” in the CALL OUT output column displays unconditionally. For the item written “Selectable” in the CALL OUT output column, you can set the condition that CALL OUT signal is output. For example, the buzzer can be set to sound when reaching the value set in “Normal Recording Area,” “Alarm Recording Area,” “LPA Recording Area,” or “Copy 2” (Setup MenuSystemRear Terminal SettingCall Out Settings) when “Buzzer” (Setup MenuSystemRear Terminal Setting) is set to “Warning.”

Key Sound

This item is used to make a sound when using the opera- tional buttons, JOG dial, and SHUTTLE ring.

Setup Menu

4 System

3 Rear Terminal Setting

step1. Set the key sound to on or off.

Buzzer

This item is used for a buzzer to sound when the remain- ing main or copy 2 device capacity reaches the value set in “Low Memory Alarm Setting” (Setup MenuSystemRear Terminal SettingMode Out Settings). Other than the above, it is possible to set the buzzer to sound when start- ing alarm recording or emergency recording, or when a warning is displayed.

To sound a buzzer only when reaching a specified remain- ing HDD capacity:

1)Set “Buzzer” to “Remain.”

2)Set the remaining capacity in “Low Memory Alarm Set- ting” (Setup Menu System Rear Terminal SettingMode Out Settings).

To sound a buzzer when reaching the specified remaining HDD capacity and when a warning is displayed:

1)Set “Buzzer” to “Warning.”

2)Set the remaining HDD capacity in the “Call Out Set- tings.” (Setup Menu System Rear Terminal SettingCall Out Settings ).

Setup Menu

4 System

3 Rear Terminal Setting

step1. Set the desired buzzer setting.

SETTING

 

 

 

 

 

BUZZER

Remain

Warning

Alarm

LAN

Off

 

 

 

 

 

 

 

 

 

 

 

When reaching the remaining

ON

OFF

OFF

OFF

OFF

capacity set in “Low Memory

 

 

 

 

 

Alarm Setting”

 

 

 

 

 

 

 

 

 

 

 

When a failure occurs and

OFF

ON

OFF

OFF

OFF

a warning is displayed

 

 

 

 

 

 

 

 

 

 

 

When an alarm recording or

OFF

OFF

ON

OFF

OFF

emergency recording is started

 

 

 

 

 

 

 

 

 

 

 

When controlling the buzzer to be

OFF

OFF

OFF

ON

OFF

sound via the personal computer

 

 

 

 

 

 

 

 

 

 

 

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations

61

Page 65
Image 65
Mitsubishi Electronics DX-TL5000U instruction manual Call Out Settings, Key Sound, Buzzer