(Alarm recording) During alarm recording, pre- alarm recording is performed at the picture grade set for alarm recording. And for only the cameras used for alarm recording,
iii)To perform with alarm recording:
Set the “Alarm Mode” to “Alarm Plus.”
•
step6. Set the alarm recording time in
Manual: Continues alarm recording until the ALARM IN terminal is not grounded.
step7. Set the recording camera for each sensor connected.
•Select “View” and display the overview screen to check the settings of all the sensors.
•The multiple camera numbers can be set for one sensor input.
step8. Set the trigger of alarm recording for each sensor connected.
External &
External &
External: Starts alarm recording only when the ALARM IN terminal is grounded.
External /
External /
•When setting the trigger to
step9. Set the PTZ camera preset.
•When the alarm input set on step 8 is input, the camera corresponding to the sensor number adjusts its angle to the preset point set on this step.
––
•Select “View” and display the overview screen to check all the settings set on steps 8 and 9.
•When the trigger is set to
Alarm recording
•When alarm recording or emergency recording is input during timer recording, the end time of the timer recording is extended until the alarm recording or the emergency recording is completed.
•When the alarm recording trigger is set to “External /
•When the alarm recording trigger is set to “External /
•When power failure occurs during alarm recording or emergency recording, the alarm recording or emergency recording is cancelled after returning from the power failure.
•When alarms are input for multiple sensors at the same time, all the alarms may not be registered to the alarm list.
Frame recording and field recording
•In NTSC signal system, one picture is consist of two screens, odd and even. The unit records only the screen of odd in case of field recording. In case of frame recording, both of the screens (odd and even) are recorded.
•Frame recording is suitable for storing the data in the high picture quality, however, the data capacity is twice as large as that of the field recording of the same picture grade (1 frame = 2 fields). The picture may be looked like vibrating because one picture is consisted by two screens.
Alarm Input
This item is used to stop the alarm input manually. When setting “Alarm Input” to “Off,” the alarm input is stopped for 5 minutes. When setting the <Recording> menu while the alarm recording occurs continuously, stop the alarm input first to stop recording. “Alarm Input” function is available for ALARM IN terminal on the rear panel, motion detection, emergency recording, and communication port. To cancel the prohibition of alarm input manually, set it to “On” or exit the <Recording> menu. It is cancelled automatically after 5 minutes.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations