(Alarm recording) During alarm recording, pre- alarm recording is performed at the picture grade set for alarm recording. And for only the cameras used for alarm recording, pre-alarm recording is performed at the alarm recording rate.

iii)To perform with alarm recording:

Set the “Alarm Mode” to “Alarm Plus.”

Pre-alarm recording is performed at the picture grade and the recording rate set for alarm recording.

Pre-alarm recording is executed with the recording rate and the picture grade of the normal or alarm recording set for that time period.

step6. Set the alarm recording time in “Post-Alarm Duration.”

Manual: Continues alarm recording until the ALARM IN terminal is not grounded.

step7. Set the recording camera for each sensor connected.

Select “View” and display the overview screen to check the settings of all the sensors.

The multiple camera numbers can be set for one sensor input.

step8. Set the trigger of alarm recording for each sensor connected.

External & MD-A: Starts alarm recording when the motion A is detected while the ALARM IN terminal is grounded.

External & MD-B: Starts alarm recording when the motion B is detected while the ALARM IN terminal is grounded.

External: Starts alarm recording only when the ALARM IN terminal is grounded.

External / MD-A: Starts alarm recording when the ALARM IN terminal is grounded or the motion A is detected.

External / MD-B: Starts alarm recording when the ALARM IN terminal is grounded or the motion B is detected.

MD-A: Starts alarm recording only when the motion A is detected.

MD-B: Starts alarm recording only when the motion B is detected.

When setting the trigger to “MD-A,” “MD-B,” “External / MD-A,” “External / MD-B,” “External & MD-A,” or “External & MD-B,” the motion detection function becomes active immediately after exiting <Set Recording Pattern A (Normal/Timer) to D (Timer)>. To stop the input of alarm signals, set the “Alarm Input” setting in the <Recording> menu to “Off.”

step9. Set the PTZ camera preset.

When the alarm input set on step 8 is input, the camera corresponding to the sensor number adjusts its angle to the preset point set on this step.

: Does not adjust the camera angle.

Select “View” and display the overview screen to check all the settings set on steps 8 and 9.

When the trigger is set to “MD-A” or “MD-B,” PTZ camera preset cannot be activated. In this case, the PTZ camera preset does not function even when the setting is set to other than “– – –.”

Alarm recording

When alarm recording or emergency recording is input during timer recording, the end time of the timer recording is extended until the alarm recording or the emergency recording is completed.

When the alarm recording trigger is set to “External / MD-A” or “External / MD-B,” the priority is given to the latest alarm input.

When the alarm recording trigger is set to “External / MD-A” or “External / MD-B,” and the alarm recording time is set to “Manual,” the alarm recording stops 2 seconds after the input of motion detection even if the ALARM IN terminal is being grounded. (When the alarm recording time for this recording according to the motion detection is set to “Manual,” the actual recording time is 2 seconds.)

When power failure occurs during alarm recording or emergency recording, the alarm recording or emergency recording is cancelled after returning from the power failure.

When alarms are input for multiple sensors at the same time, all the alarms may not be registered to the alarm list.

Frame recording and field recording

In NTSC signal system, one picture is consist of two screens, odd and even. The unit records only the screen of odd in case of field recording. In case of frame recording, both of the screens (odd and even) are recorded.

Frame recording is suitable for storing the data in the high picture quality, however, the data capacity is twice as large as that of the field recording of the same picture grade (1 frame = 2 fields). The picture may be looked like vibrating because one picture is consisted by two screens.

Alarm Input

This item is used to stop the alarm input manually. When setting “Alarm Input” to “Off,” the alarm input is stopped for 5 minutes. When setting the <Recording> menu while the alarm recording occurs continuously, stop the alarm input first to stop recording. “Alarm Input” function is available for ALARM IN terminal on the rear panel, motion detection, emergency recording, and communication port. To cancel the prohibition of alarm input manually, set it to “On” or exit the <Recording> menu. It is cancelled automatically after 5 minutes.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations