Functional Description

When any bit in the MPC Error Status register is set, the Raven ASIC will attempt to latch as much information as possible about the error in the MPC Error Address and Attribute registers. Information is saved as follows:

Error Status

Error Address

and Attributes

 

 

 

MATO

From MPC bus

 

 

SMA

From PCI bus

 

 

RTA

From PCI bus

 

 

PERR

Invalid

 

 

SERR

Invalid

 

 

Each MERST error bit may be programmed to generate a machine check and/or a standard interrupt. The error response is programmed through the MPC Error Enable register on a source-by-source basis. When a machine check is enabled, either the MID field in the MPC Error Attribute register or the DFLT bit in the MEREN register determine the master to which the machine check is directed. For errors in which the master that originated the transaction can be determined, the MID field is used, provided the MID is%00 (processor 0), %01 (processor 1), or %10 (processor 2). For errors not associated with a particular MPC master, or associated with masters other than processor 0, 1, or 2, the DFLT bit is used. One example of an error condition which cannot be associated with a particular MPC master would be a PCI system error.

2

Transaction Ordering

The Raven ASIC supports transaction ordering with an optional FIFO flushing option. The FLBRD (Flush Before Read) bit within the GCSR register controls the flushing of PCI write-posted data when performing MPC-originated read transactions.

http://www.motorola.com/computer/literature