OnCell G2150I AT Command Set

Network Service Commands

 

 

 

 

AT+COPS=2

OK

 

Note: Ask for deregistration from network

Note: Succeeded

 

AT+COPS?

+COPS: 2

 

Note: Ask for current PLMN

Note: ME is unregistered until <mode>=0

 

 

or 1 is selected

Defined values: <mode>

0:automatic (default value)

1:manual

2:deregistration; ME will be unregistered until <mode>=0 or 1 is selected.

3:set only <format> (for read command AT+COPS?)

4:manual / automatic (<oper> shall be present), if manual selection fails, automatic mode is entered.

<format>: format of <oper> field

0:long alphanumeric format <oper>

1:short alphanumeric format <oper>

2:numeric <oper> (default value) <stat>: status of <oper>

0:unknown

1:available

2:current

3:forbidden

<oper>: operator identifier (MCC/MNC in numeric format only for operator selection) The long alphanumeric format can be up to 16 characters long (see appendix 19 Codes and values for operator names description, field is “Name”). The short alphanumeric format can be up to 10 characters long.

Network Registration: +CREG

Description: This command is used by the application to ascertain the registration status of the product.

Command syntax: AT+CREG= <mode>

+CREG: <mode>, <stat> [ ,<lac>,<ci> ] for AT+CREG? command only

 

 

Command

Possible responses

AT+CREG?

+CREG: <mode>,<stat>

 

OK

 

Note: As defined here-above

AT+CREG=0

OK

Note: Disable network registration unsolicited

Note: Command valid

result code

 

AT+CREG=1

OK

Note: Enable network registration unsolicited

Note: Command valid

result code

 

AT+CREG=2

OK

Note: Enable network registration and location

Note: Command valid

information unsolicited result code

 

AT+CREG=?

+CREG: (0-2)

 

Note: 0,1,2 <mode> values are supported

Defined values:

 

<mode>

 

5-4

 

Page 39
Image 39
Moxa Technologies G2150I manual Network Registration +CREG, Or 1 is selected, Command syntax AT+CREG= mode, Result code