OnCell G2150I AT Command Set

V24-V25 Commands

Data / Commands Multiplexing: +WMUX

Description: This specific command allows managing the data / AT commands multiplexing

Command syntax:

AT+WMUX=<mode>

 

 

 

Command

 

Possible responses

AT+WMUX=?

 

+WMUX: (0-1) OK

AT+WMUX?

 

+WMUX: 0

 

 

OK

 

 

Note: Data / Commands multiplexing disabled.

AT+WMUX=1

 

OK

Note: Enable Data / Commands

 

multiplexing.

 

 

Defined values: <mode>

0:Multiplexing disabled. When the product is online (data communication in progress), no AT command can be used (default).

1:Multiplexing enabled. Data flows and AT commands are multiplexed while in online

mode (data communication in progress).

Note: The Multiplexing mode is available to only one UART. If this mode is available on UART1 and the AT+WMUX=1 command is sent through UART2, the multiplexing mode will be available on UART2 and disabled on UART1.