Call Control Commands

 

activated using +CLCK command). Voice call (with semi-colon).

AT%D1

Activates automatic DTR dialing if DTR switches from OFF to ON; Dials the

 

phone number in the first location of the ADN phonebook (or FDN phonebook, if

 

it is activated using +CLCK command). Data or Fax call (without semi-colon).

AT%D2

Activates automatic DTR short message transmission if DTR switches from OFF

 

to ON. Sends the short message in the first location of the SIM.

If the first location is empty:

AT%D1 and AT%D2 commands will receive an OK response

The DTR ON event will trigger a CME ERROR: 21 or a CMS ERROR: 321.

Automatic Answer: ATS0

Description: This S0 parameter determines and controls the product automatic answering mode.

Command syntax: ATS0=<value>

Command

Possible responses

ATS0=2

OK

Note: Automatic answer after 2 rings

 

ATS0?

002

Note: Current value

OK

Note: always 3 characters padded with zeros

ATS0=0

OK

Note: No automatic answer

Note: Command valid

All others S-parameters (S6,S7,S8 …) are not implemented. Defined values: <value>

number of rings before automatic answer (3 characters padded with zeros). Range of values is 0 to 255

Incoming Call Bearer: +CICB

Description: This specific command is used to set the type of incoming calls when no incoming bearer is given (see +CSNS).

Note: setting the +CICB command affects the current value of +CSNS.

Command syntax: AT+CICB=<mode>

Command

Possible responses

AT+CICB=1

OK

Note: If no incoming bearer, force a fax call

Note: Command accepted

AT+CICB=2

OK

Note: If no incoming bearer, force a voice call

Note: Command accepted

AT+CICB?

+CICB: 2

Note: Interrogate value

OK

Note: Default incoming bearer: voice call

AT+CICB=?

+CICB: (0-2)

 

OK

Note: Test command

Note: Speech, data or fax default incoming

bearer

Defined values: <mode>

0:Data

1:Fax

2:Speech