Chapter 11 Serial Interface 0, 1

„Serial Interface 0 Mode Register 3 (SC0MD3)

All flags are only for reading.

SC0MD3

7

6

5

4

3

2

1

0

 

SC0TBSY

SC0RBSY

SC0TEMP

SC0REMP

SC0FEF

SC0PEK

SC0ORE

SC0ERE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(At reset : 0 0 0 0 0 0 0 0 )

SC0ERE

Error monitor flag

0No error

1Error

SC0ORE

Overrun error detection

0No error

1Error

SC0PEK

Parity error detection

0No error

1Error

SC0FEF

Framing error detection

0No error

1Error

SC0REMP

Receive buffer empty flag

0Empty

1Full

SC0TEMP

Transfer buffer empty flag

0Empty

1Full

SC0RBSY

Serial bus status

0Other use

1Serial reception in progress

SC0TBSY

Serial bus status

0Other use

1Serial transmission in progress

Figure 11-2-6 Serial Interface 0 Mode Register 3 (SC0MD3 : x'03F95', R)

Control Registers XI - 11

Page 337
Image 337