Panasonic MN101C77C, F77G user manual Xvii 8 Special Function Registers List

Models: F77G MN101C77C

1 544
Download 544 pages 59.61 Kb
Page 508
Image 508

Chapter 17 Appendices

Address

Register

 

 

 

 

 

 

Bit Symbol /Initial Value /Description

 

 

Page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 7

 

 

 

Bit 6

Bit 5

 

Bit 4

Bit 3

 

 

 

Bit 2

 

 

Bit 1

Bit 0

 

 

 

 

P6DIR7

 

 

 

P6DIR6

P6DIR5

 

P6DIR4

P6DIR3

 

 

 

P6DIR2

 

 

P6DIR1

P6DIR0

 

X'3F36'

P6DIR

 

 

 

 

 

 

 

 

Port 6 I/O Direction Control

 

 

 

 

 

IV - 27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P7DIR7

 

 

P7DIR6

 

P7DIR5

 

P7DIR4

P7DIR3

 

 

P7DIR2

 

 

P7DIR1

P7DIR0

 

X'3F37'

P7DIR

 

 

 

 

 

 

 

 

Port 7 I/O Direction Control

 

 

 

 

 

IV - 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P8DIR7

 

 

P8DIR6

 

P8DIR5

 

P8DIR4

P8DIR3

 

 

P8DIR2

 

 

P8DIR1

P8DIR0

 

X'3F38'

P8DIR

 

 

 

 

 

 

 

 

Port 8 I/O Direction Control

 

 

 

 

 

IV - 38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

PADIR6

PADIR5

 

PADIR4

PADIR3

 

 

PADIR2

 

PADIR1

PADIR0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F3A'

PADIR

 

 

 

 

 

 

 

 

Port A I/O Direction Control

 

 

 

 

 

IV - 42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

PAIMD6

 

PAIMD5

 

PAIMD4

PAIMD3

 

 

PAIMD2

 

 

PAIMD1

PAIMD0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F3C'

PAIMD

 

 

 

 

 

 

 

 

 

Port A Analog Input Selection

 

 

IV - 43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IRQ4SEL

 

-

 

-

 

-

P6KYEN4

 

 

P6KYEN3

 

 

P6KYEN2

P6KYEN1

 

X'3F3E'

P6IMD

IRQ4 Interrupt

 

 

 

 

 

 

 

Port 6 Key Input Interrupt Pin Setup

III - 46

 

 

 

Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

P0PLU6

 

P0PLU5

 

P0PLU4

P0PLU3

 

 

P0PLU2

 

 

P0PLU1

P0PLU0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F40'

P0PLU

 

 

 

 

 

 

 

 

Port 0 Pull-up Control

 

 

 

 

 

IV - 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

-

 

-

 

P1PLU4

P1PLU3

 

 

P1PLU2

 

 

P1PLU1

P1PLU0

 

X'3F41'

P1PLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IV - 13

 

 

 

 

 

 

 

 

 

Port 1 Pull-up Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

-

 

-

 

P2PLU4

P2PLU3

 

 

P2PLU2

 

 

P2PLU1

P2PLU0

 

X'3F42'

P2PLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IV - 18

 

 

 

 

 

 

 

 

 

Port 2 Pull-up Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

-

 

-

 

P5PLU4

P5PLU3

 

 

P5PLU2

 

 

P5PLU1

P5PLU0

 

X'3F45'

P5PLU

 

 

 

 

 

 

 

 

 

Port 5 Pull-up Control

 

IV - 22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P6PLU7

 

 

P6PLU6

 

P6PLU5

 

P6PLU4

P6PLU3

 

 

P6PLU2

 

 

P6PLU1

P6PLU0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F46'

P6PLU

 

 

 

 

 

 

 

 

Port 6 Pull-up Control

 

 

 

 

 

IV - 27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P7PLUD7

 

 

P7PLUD6

 

P7PLUD5

 

P7PLUD4

P7PLUD3

 

 

P7PLUD2

 

 

P7PLUD1

P7PLUD0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F47'

P7PLUD

 

 

 

 

 

 

 

Port 7 Pull-up/Pull-down Control

 

 

 

 

 

IV - 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P8PLU7

 

 

P8PLU6

 

P8PLU5

 

P8PLU4

P8PLU3

 

 

P8PLU2

 

 

P8PLU1

P8PLU0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F48'

P8PLU

 

 

 

 

 

 

 

 

Port 8 Pull-up Control

 

 

 

 

 

IV - 38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

PAPLUD6

PAPLUD5

 

PAPLUD4

PAPLUD3

 

 

PAPLUD2

 

 

PAPLUD1

PAPLUD0

 

X'3F4A'

PAPLUD

 

 

 

 

 

 

 

 

Port A Pull-up/Pull-down Control

 

 

IV - 42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUZOE

 

 

BUZS2

 

BUZS1

 

BUZS0

DLYS2

 

 

DLYS1

 

 

DLYS0

-

II - 41

X'3F4D'

DLYCTR

Buzzer Output

 

 

Buzzer Output Frequency Selection

Osscillation Stabilization

 

 

 

 

X - 3

 

 

 

Enable

 

 

 

 

 

 

 

Wait Time Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM0BC7

 

 

TM0BC6

 

TM0BC5

 

TM0BC4

TM0BC3

 

 

TM0BC2

 

 

TM0BC1

TM0BC0

 

 

 

 

 

 

 

 

 

 

 

 

 

X'3F50'

TM0BC

 

 

 

 

 

 

 

 

Timer 0 Binary Counter

 

 

 

 

 

VI - 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM1BC7

 

 

TM1BC6

TM1BC5

 

TM1BC4

TM1BC3

 

TM1BC2

 

TM1BC1

TM1BC0

 

X'3F51'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM1BC

 

 

 

 

 

 

 

 

Timer 1 Binary Counter

 

 

 

 

 

VI - 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM0OC7

 

 

TM0OC6

TM0OC5

 

TM0OC4

TM0OC3

 

TM0OC2

 

TM0OC1

TM0OC0

 

X'3F52'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM0OC

 

 

 

 

 

 

Timer 0 Output Compare Register

 

 

VI - 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XVII - 8 Special Function Registers List

Page 508
Image 508
Panasonic MN101C77C, F77G user manual Xvii 8 Special Function Registers List