Chapter 11 Serial Interface 0, 1

11-3-8 Setup Example

„Transmission / Reception Setup

The setup example at UART transmission / reception with serial 0 is shown. Table 11-3-33 shows the conditions at transmission / reception.

Table 11-3-33 UART Interface Transmision Reception Setup

Setup item

set to

 

 

TXD / RXD pin

independent (with 2 channels)

Frame mode specification

8 bits + 2 stop bits

 

 

First transfer bit

MSB

 

 

Clock source

timer 5

 

 

Used pin

A (Port 0)

 

 

TXD0A / RX0DA pin type

Nch open-drain

 

 

Pull-up resistor of TXD0A pin

added

Parity bit add / check

"0"add / check

 

 

Serial interface 0 transmission

Enable.

complete interrupt

 

Serial interface 0 reception

Enable.

complete interrupt

 

An example setup procedure, with a description of each step is shown below.

 

Setup Procedure

 

Description

 

 

 

(1)

Select prescaler operation.

(1) Set the PSCEN flag of the PSCMD register to

 

PSCMD (x'3F6F')

 

"1" to select prescaler operation.

 

bp0 : PSCEN = 1

 

 

(2) Select the clock source.

(2)

Set the bp2 - 0 flag of the SC0CKS

 

SC0CKS (x'3F97')

 

register to "110" to select timer 4 output as a

 

bp2-0 : SC0PSC2-0 = 110

 

clock source.

(3)

Select the used pin.

(3)

Set the SC0SEL flag of the SC0ODC

 

SC0ODC(x'3F96')

 

register to "0" to set I/O used pin to A (port 0).

 

bp7 : SC0SEL = 0

 

 

(4)

Control the pin type.

(4)

Set the SC0ODC0 flag of the SC0ODC

 

SC0ODC(x'3F96')

 

register to "1" to select N-ch open drain for the

 

bp0 : SC0ODC0 = 1

 

TXD0A pin. Set the P0PLU3 flag of the P0PLU

 

P0PLU (x'3F40')

 

register to "1" to add pull-up resistor.

 

bp3 : P0PLU3 = 1

 

 

(5)

Control the pin direction.

(5)

Set the P0DIR4-3 flag of the port 0 pin direction

 

P0DIR(x'3F30')

 

control register (P0DIR) to "01" to set P03 to

 

bp4-3 : P0DIR4-3 = 01

 

output mode, and P04 to input mode.

 

 

 

 

XI - 58 Operation