Panasonic MN101C77C, F77G „A/D Converter Control Register 1 ANCTR1, ANCTR2 Anst, Anstsel

Models: F77G MN101C77C

1 544
Download 544 pages 59.61 Kb
Page 480
Image 480

Chapter 15 A/D Converter

„A/D Converter Control Register 1 (ANCTR1)

 

7

6

5

4

3

2

1

0

 

ANCTR1

-

-

-

-

RESERVED

ANCHS2

ANCHS1

ANCHS0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(At reset : - - - - 0 0 0 0)

ANCHS2

ANCHS1

ANCHS0

Analog Input Channel

 

 

 

 

 

0

0

AN0 (PA0)

0

1

AN1 (PA1)

 

 

 

 

1

0

AN2 (PA2)

 

 

1

AN3 (PA3)

 

 

 

 

 

 

 

0

0

AN4 (PA4)

1

1

AN5 (PA5)

 

1

0

AN6 (PA6)

 

 

1

Reserved

 

 

 

 

 

 

RESERVED Set always "0".

Figure 15-2-2 A/D Converter Control Register 1 (ANCTR1 : x'03FB1', R/W)

„A/D Converter Control Register 2 (ANCTR2)

 

7

6

5

4

3

2

1

0

ANCTR2

ANST

ANSTSEL

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

(At reset : 0 0 - - - - - - )

ANSTSEL

0

1

ANST

0

1

A/D conversion activation factor selection

Set the ANST flag to "1".

Set the ANST flag, or the external interrupt 3 to "1".

A/D conversion status

A/D conversion is completed, stopped

A/D conversion is started, in progress

Figure 15-2-3 A/D Converter Control Register 2 (ANCTR2 : x'03FB2', R/W)

XV - 6 Control Registers

Page 480
Image 480
Panasonic MN101C77C, F77G „A/D Converter Control Register 1 ANCTR1, „A/D Converter Control Register 2 ANCTR2, ANCTR2 Anst