Chapter 5 Prescaler

5-3 Operation

5-3-1 Operation

„Prescaler Operation (Prescaler 0 to 1)

Prescaler 0 is a 7-bit and prescaler 1 is a 3-bit free-running counter that divides the base clock. This prescaler can be started or stopped by the PSCEN flag of the prescaler control register (PSCMD).

„Count Timing of Prescaler Operation (Prescaler 0 and 1) Prescaler 0 counts up at the falling edge of fosc. Prescaler 1 counts up at the falling edge of fs.

„Peripheral Functions with Prescaler Output Cycle Clock

Table 5-3-1 shows the prescaler output clock source that the peripheral functions can be used, and the registers that control the clock source selection.

Table 5-3-1 Peripheral Functions Used with Prescaler Output Cycle Clock

 

Peripheral functions

Control register

 

 

 

External interrupt 0

Noise filter sampling clock

-

 

 

 

External interrupt 1

Noise filter sampling clock

-

 

 

 

Timer 0

Count clock

CK0MD

 

 

 

Timer 1

Count clock

CK1MD

 

 

 

Timer 4

Count clock

CK4MD

 

 

 

Timer 5

Count clock

CK5MD

 

 

 

Serial 0

Transfer clock

SC0CKS

 

 

 

Serial 1

Transfer clock

SC1CKS

 

 

 

Serial 3

Transfer clock

SC3CKS

 

 

 

When the prescaler output clock source is used, counting of prescaler should be enabled before starting the peripheral functions.

Operation V - 11