Chapter 15 A/D Converter

Setup Procedure

 

Description

(7) Set the A/D ladder resistance.

(7)

Set the ANLADE flag of the A/D converter

ANCTR0(x'3FB0')

 

control register 0 (ANCTR0) to "1" to send a

bp3 : ANLADE = 1

 

current to the ladder resistance for the A/D

 

 

conversion.

(8) Start the A/D conversion.

(8)

Set the ANSTSEL flag of the A/D converter

ANCTR2(x'3FB2')

 

control register 2 (ANCTR2) to "0", and select

bp6 : ANSTSEL = 0

 

"writing to the ANST flag of the A/D converter

 

 

control register 2 (ANCTR2)"as the A/D

 

 

converter activation factor.

(9) Start the A/D conversion operation.

(9) Set the ANST flag of the A/D converter control

ANCTR2 (x'3FB2')

 

register 2 (ANCTR2) to "1" to start the A/D

bp7 : ANST = 1

 

conversion.

(10) Complete the A/D conversion.

(10)

When the A/D conversion is finished, the A/D

ANBUF0 (x'3FB3')

 

conversion complete interrupt is generated

ANBUF1 (x'3FB4')

 

and the ANST flag of the A/D converter control

 

 

register 2 (ANCTR2) is cleared to "0". The

 

 

result of the conversion is stored to the A/D

 

 

converter buffer (ANBUF0, 1).

 

 

 

Note : The above (3) to (4) can be set at once.

Start the A/D conversion after the current flowing through the ladder resistors stabilizes. The wait time should be decided by the caluculated times from the ladder resistance (max. 80 k), and the external bypass capacitor connected between VREF+ and VREF-.

Operation XV - 13