Panasonic MN101C77C, F77G user manual Transmission Timing Falling edge, Enable Start Condition

Models: F77G MN101C77C

1 544
Download 544 pages 59.61 Kb
Page 400
Image 400

Chapter 12 Serial Interface 3

„Transmission Timing

at master

at slave

Tmax=2.5 T T

Tmax=1.5 T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock (SBT3 pin)

Output data (SBO3 pin)

Transfer bit counter

0

1

2

3

4

5

6

7

SC3BSY

(Write data to SC3TRB) Interrupt

(SC3IRQ)

Figure 12-3-2 Transmission Timing (Falling edge, Enable Start Condition)

at master

 

at slave

Tmax=1.5 T

T

Tmax=1.5 T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock (SBT3 pin)

Output data (SBO3 pin)

Transfer bit counter

0

1

2

3

4

5

6

7

SC3BSY

(Write data to SC3TRB) Interrupt

(SC3IRQ)

Figure 12-3-3 Transmission Timing (Falling edge, Disable Start Condition)

XII - 14 Operation