Chapter 14 Automatic Transfer Controller

To execute a continuous serial transaction, you must pre-store the serial transmission data in the memory space that memory pointer 0 points, the transmission data must fill every other address in the space. Once the serial transaction ends, the received data is stored empty (skipped) addresses and the transmission and reception data at stored in an alternating pattern.

In transfer mode 6, ATC1 executes a data byte transfer twice each time it is activated. The value in memory pointer 0 increments by one each time a byte-length data transfer ends. As a result, the source address for the next ATC1 operation is two addresses higher than that for the previous operation.

Set the data transfer count for ATC1 in the transfer data counter (AT1TRC). The counter can be set to a maximum of 255 transfers. The counter decrements each time ATC1 is activated (after one byte of data has been transferred twice). When it reaches x'00', an interrupt (ATC1IRQ) occurs and the automatic transfer ends.

Operation XIV - 21