Panasonic F77G, MN101C77C user manual Converter

Models: F77G MN101C77C

1 544
Download 544 pages 59.61 Kb
Page 489
Image 489

Chapter 15 A/D Converter

Setup Procedure

 

Description

 

 

 

(7) Enable the interrupt.

(7)

Enable the interrupt by setting the ADIE flag of

ADICR(x'3FFA')

the

ADICR register to "1".

bp1 : ADIE = 1

 

 

(8) Set the A/D ladder resistance.

(8)

Set the ANLADE flag of the A/D converter

ANCTR0(x'3FB0')

 

control register 0 (ANCTR0) to "1" to send a

bp3 : ANLADE = 1

 

current to the ladder resistance for the A/D

 

 

conversion.

(9) Select the A/D converter activation

(9)

Set the ANSTSEL flag of the A/D converter

factor.

 

control register 2 (ANCTR2) to "1", and select

ANCTR2 (x'3FB2')

 

"writing to the ANST flag of the A/D converter

bp6 : ANSTSEL = 1

 

control register 3 (ANCTR3), the external

 

 

interrupt 3"as the A/D converter activation

 

 

factor.

(10) Start the A/D conversion.

(10) When the external interrupt 3, set in (5) is

ANCTR2 (x'3FB2')

 

generated, the ANST flag of the A/D converter

bp7 : ANST = 1

 

control register 2 (ANCTR2) is set to "1" to start

 

 

the A/D conversion. And even if the external

 

 

interrupt 3 is not generated, the A/D conversion

 

 

is started by setting the ANST flag of the A/D

 

 

converter control register 2 (ANCTR2) to "1".

(11) Complete the A/D conversion.

(11)

When the A/D conversion is finished, the A/D

 

 

conversion complete interrupt is generated,

 

 

and the ANST flag of the A/D converter control

 

 

register 2 (ANCTR2) is cleared to "0".

 

 

The result of the conversion is stored to the A/D

 

 

converter buffer (ANBUF0, 1).

 

 

 

Note : The above (3) to (4) can be set at once.

Even if the external interrupt 3 is generated during A/D conversion, the A/D converter is operated in normal. Also, once the A/D conversion is finished, it is never started again.

Operation XV - 15