ProSafe Gigabit 8 Port VPN Firewall FVS318G Reference Manual

Problems with the date and time function can include:

Date and time shown is Thu Jan 01 00:01:52 GMT 1970. Cause: The VPN firewall has not yet successfully reached a Network Time Server. Check that your Internet access settings are configured correctly. If you have just completed configuring the VPN firewall, wait at least five minutes and check the date and time again.

Time is off by one hour. Cause: The VPN firewall does not automatically sense Daylight Savings Time. Go to the Time Zone screen (see “Configuring Date and Time Service” on page 6-21), and select or deselect the checkbox marked “Automatically Adjust for Daylight Savings Time”.

Using the Diagnostics Utilities

You can perform diagnostics such as pinging an IP address, performing a DNS lookup, displaying the routing table, rebooting the VPN firewall, and capturing packets.

Note: For normal operation, diagnostics are not required.

Select Monitoring from the main menu and Diagnostics from the submenu. The Diagnostics screen displays.

Figure 7-1

7-8

Troubleshooting

v1.1, August 2010

Page 200
Image 200
NETGEAR FVS318G manual Using the Diagnostics Utilities