3. Perceived 5250 Host Problems

The first problems in this category are for when there are other users who have Telnet sessions working.

Problem 3.1

You do not know the IP Address of the AS/400.

Solution

You will need access to the AS/400's command line from another terminal device or your system administrator to provide you with the correct IP address for the AS/400 that you want to connect to. For those that don't know, or would like to know the AS/400 command is as follows:

1.After signing on to the AS/400 with the appropriate privileges, from the command line type CFGTCP followed by the <enter> key.

2.On the next screen, select option Work with TCP/IP Interfaces, by typing a 1 and then <enter>.

3.Locate the interface that you are going to connect to. (If you only see 127.0.0.1 this means TCP/IP has not been properly configured on your AS/400. DO NOT use 127.0.0.1.

If you do so you will NEVER get a sign on from the AS/400. If TCP/IP is not configured on your AS/400 we recommend you follow the instructions from IBM. The name of the book is called "Getting Your AS/400 Working for You". Publication number is SC41- 5161-00. You'll find helpful information on TCP/IP in Chapter 6.) Write down the IP address and enter that in the MinIT 6000 configuration for this session’s Host Configuration – IP Address.

Problem 3.2

It was working. The light on the MinIT 6000 is green. The MinIT 6000 host session is black, with no cursor.

Possible Cause 3.2.1

You have lost your IP connection. You could have a cable break, hub, bridge, or router down. This means that you are not accessing a valid IP address, or the Ethernet line is not up or MinIT 6000 or the host configuration was changed.

Action

1.Verify physical connection. Viewing lights is the usually the quickest way to do this.

2.See if others users are working, if not check the AS400 configuration.

3.Swap devices if possible to see if the problem follows the device in question.

Possible Cause 3.2.2

Disconnecting the session when you are not at a signon screen could cause this problem. This could also happen if you had a power outage and MinIT 6000 crashed and you had to re-boot. The AS/400 still has your session active, although in a crashed status.

Solution

If the last device using this station address crashed, the station address may be varied off. Ask the System Administrator to vary your device on. This may require varying off, then

Page 121
Image 121
Nlynx MinIT6000 user manual Perceived 5250 Host Problems, Possible Cause