Chapter 4Settings — [P IN P] menu

12)If [CLOCK PHASE] is selected in Step 6), press qw to make adjustment.13)Press as to select [FRAME LOCK].

14)Press qw to switch the item.

[MAIN WINDOW]

Set frame lock to the input signal set in the main window.

[SUB WINDOW]

Set frame lock to the input signal set in the sub window.

15)Press as to select [TYPE].16)Press qw to switch the item.

[MAIN WINDOW]

The main window has display priority.

[SUB WINDOW]

The sub window has display priority.

Note

ff The P IN P function may not be available for some signals being input or terminals being selected. Refer to “Two-window display combination list” (x page 174) for details.

ff The main window setting values are applied to image adjustment values such as [PICTURE MODE], [GAMMA], and [COLOR TEMPERATURE].

ff On the main screen (when no menu is displayed), press qw to switch the sizes and positions of the main window and sub window while P IN P is operating.

ff When [FRAME RESPONSE] is set to other than [NORMAL], [P IN P] cannot be set.

ff 3D images cannot be displayed in P IN P. (Only for PT‑DZ13KU, PT‑DS12KU, PT‑DW11KU)

ff The P IN P state continues while the P IN P function is used, even if 3D images of the simultaneous system are displayed. (Only for

PT‑DZ13KU, PT‑DS12KU, PT‑DW11KU)

126 - ENGLISH