Chapter 6Appendix — Technical information

Control command

The following table lists the commands that can be used to control the projector using a computer.

rrProjector control command

Command

Details

Parameter/responseRemark (parameter)

string

 

 

 

PON

Power on

To check if the power is on, use the “Power query” command.

POF

Power standby

 

 

QPW

Power query

000

STANDBY

001

Power on

 

 

 

 

VID

VIDEO

 

 

RG1

RGB1

 

Switching the input

RG2

RGB2

IIS

DVI

DVI‑D

signal

 

HD1

HDMI

 

 

 

 

SD1

SDI1 (only for PT‑DZ13KU, PT‑DS12KU, PT‑DZ10KU)

 

 

SD2

SDI2 (only for PT‑DZ13KU, PT‑DS12KU)

 

 

0

DUAL

QSL

Query for lamp selection

1

SINGLE

2

LAMP1

 

 

3

LAMP2

 

 

0

DUAL

LPM

Lamp selection

1

SINGLE*1

2

LAMP1

 

 

 

 

3

LAMP2

 

 

0

HIGH (only for PT‑DZ13KU, PT‑DS12KU, PT‑DW11KU)

 

 

NORMAL (only for PT‑DZ10KU)

OLP

Lamp power

 

1

ECO

 

 

 

 

8

MIDDLE (only for PT‑DZ13KU, PT‑DS12KU, PT‑DW11KU)

 

Lamp cumulative

1

LAMP1

Q$L

2

LAMP2

runtime query

 

 

Response is 0000 to 4000

 

 

 

OSH

Shutter

0

OPEN

QSH

Shutter status query

1

CLOSE

 

 

0

DEFAULT/VID AUTO

VSE

Aspect ratio switch

1

4:3

2

16:9

 

 

 

 

5

THROUGH

 

Aspect ratio settings

6

HV FIT

QSE

9

H FIT

query

 

10

V FIT

 

 

 

 

0

OFF

OPP

P IN P execute

1

USER1

2

USER2

 

 

 

 

3

USER3

 

 

0

OFF

QPP

P IN P setting query

1

USER1

2

USER2

 

 

 

 

3

USER3

OCS

Sub memory switch

 

 

QSB

Sub memory status

01 - 96

Sub memory number

query

 

 

 

 

 

*1 Use Lamp 1 or Lamp 2 whichever has a shorter runtime.

 