Chapter 5Maintenance — Lamp/temperature/filter indicators

Temperature indicator <TEMP>

Indicator status

 

Lighting in red

Flashing in red

Flashing in red

 

(2 times)

(3 times)

 

 

 

 

Status

Warm-up status

Internal temperature is high

Internal temperature is high

The cooling fan has

(warning).

(standby status).

stopped.

 

 

 

 

ff Did you turn on the power

ff Is the air intake/exhaust port blocked?

 

Cause

 

when the temperature

ff Is the room temperature high?

 

was low (around 0 °C

 

 

ff Is the filter indicator <FILTER> lit?

 

 

 

(32 °F))?

 

 

 

 

 

 

 

ff Wait at least five minutes

ff Remove any objects that are blocking the air intake/

 

 

 

in the current status.

exhaust port.

 

ff Turn the <MAIN POWER>

 

 

ff Install the projector in a location with an ambient

 

f

f Install the projector in a

switch to <OFF>

Solution

temperature of 0 °C (32 °F) to 45 °C (113 °F)*1.

 

(x page 55), and

 

 

location with an ambient

ff Do not use the projector at high altitudes of 2 700 m

 

 

temperature of 0 °C

consult your dealer.

 

 

(8 858') or higher above sea level.

 

 

(32 °F) to 45 °C (113 °F)*1.

 

 

 

ff Clean or replace the air filter unit. (x page 157)

 

 

 

 

 

*1 When using the projector at high altitudes (1 400 m (4 593') or higher – lower than 2 700 m (8 858') above sea level), the operating environment temperature should be between 0 °C (32 °F) and 40 °C (104 °F).

If you use the Smoke cut filter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be used at high altitudes.

If you use the Replacement lamp unit (for portrait mode), the operating environment temperature should be between 0 °C (32 °F) and 40 °C

(104 °F) when using the projector at elevations lower than 1 400 m (4 593') above sea level, and between 0 °C (32 °F) and 35 °C (95 °F) when using the projector at high altitudes. If you use the Smoke cut filter together, the operating environment temperature should be between 0 °C (32 °F) and 30 °C (86 °F).

Note

ff If the temperature indicator <TEMP> is still lit or flashing after taking the preceding measures, ask your dealer for repair.

ff If you use the projector with the following two settings made, the light output may drop by approx. 20 % to protect the projector when an ambient temperature becomes 40 °C (104 °F) or higher (35 °C (95 °F) or higher if [HIGH ALTITUDE MODE] is set to [ON], or if the Smoke cut filter is used).

gg When [LAMP SELECT] is set to [DUAL] from the menu

gg When [LAMP POWER] is set to [HIGH], [MIDDLE], or [NORMAL] from the menu

Filter indicator <FILTER>

Indicator status

 

Lighting in red

 

Flashing in red

Status

The filter is clogged.

 

 

The air filter unit is not

The temperature inside or outside the projector is abnormally high.

attached.

 

Cause

ff Is the air filter unit dirty?

ff Is the air intake/exhaust

ff Is [HIGH ALTITUDE

ff Is the air filter unit

port blocked?

MODE] set correctly?

attached?

 

 

 

 

 

ff When using the projector

 

 

 

 

at high altitudes between

 

 

 

 

1 400 m (4 593') or higher

 

 

 

 

and lower than 2 700 m

 

 

 

ff Remove any objects that

(8 858') above sea level,

 

Solution

ff Clean or replace the air

set [HIGH ALTITUDE

ff Attach the air filter unit.

are blocking the air intake/

filter unit. (x page 157)

MODE] (x page 109) to

 

exhaust port.

 

 

 

[ON].

 

 

 

 

 

 

 

 

ff Do not use the projector

 

 

 

 

at high altitudes of

 

 

 

 

2 700 m (8 858') or higher

 

 

 

 

above sea level.

 

Note

ff If the filter indicator <FILTER> is still lit or flashing after taking the preceding measures, ask your dealer for repair.

ff If the filter is clogged, only one lamp may light even when [LAMP SELECT] is set to [DUAL]. By cleaning the air filter unit or replacing it with a new one, the lamp will light properly.

156 - ENGLISH