Chapter 4Settings — [NETWORK] menu

[E-mail set up] page

When there is a problem or the runtime of a lamp reaches a set value, an E-mail can be sent to preset E-mail addresses (up to two addresses).

Click [Detailed set up] [E-mail set up].

1[ENABLE]

Select [Enable] to use the E-mail function.

2[SMTP SERVER NAME]

Enter the IP address or the server name of the E-mail server

(SMTP). To enter the server name, the DNS server needs to be set up.

3[MAIL FROM]

Enter the E-mail address of the projector. (Up to 63 characters in single byte)

4[MEMO]

Enter information such as the location of the projector that notifies the sender of the E-mail. (Up to 63 characters in single byte)

1

2

3

4

5

6

5[MINIMUM TIME]

Change the minimum interval for the temperature warning E-mail. The default value is 60 minutes. In this case, another E-mail will not be sent for 60 minutes after sending the temperature warning E-mail even if it reaches the warning temperature.

6[INTAKE AIR TEMPERATURE]

Change the temperature setting for the temperature warning mail. A temperature warning E-mail is sent when the temperature exceeds this value.

ENGLISH - 145