Chapter 4Settings — [3D SETTINGS] menu

[3D WAVEFORM MONITOR]

[OFF]

Hides the 3D waveform monitor.

[ON]

Displays the 3D waveform monitor.

 

Note

ff The [CLOCK PHASE] setting is enabled at simultaneous input of RGB1 and RGB2 to adjust the right eye image. ff This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].

ff This is disabled when [3D TEST PATTERN] is displayed.

ff This is disabled when [3D TEST MODE] is set to other than [NORMAL] or [SIDE BY SIDE].

ff The 3D waveform monitor is displayed only when the [3D PICTURE BALANCE] screen is displayed. ff The normal waveform monitor cannot be displayed in 3D images.

[DARK TIME SETTING]

Set the black display period to be displayed between the right eye image and the left eye image as necessary for the 3D system used.

1)Press as to select [DARK TIME SETTING].

2)Press qw to switch the item.

ff The items will switch each time you press the button.

[0.5 ms][1.0 ms][1.5 ms][2.0 ms][2.5 ms][2.7 ms]

Note

Set so that the 3D setting is displayed correctly.

ff This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].

ff When the setting does not correspond to the 3D system in use, phenomenon such as increased crosstalk and darkening of displayed images may occur.

[3D FRAME DELAY]

Adjust the timing of the left-right switch of an image.

1)Press as to select [3D FRAME DELAY].

2)Press qw to switch the item.

[0us] - [25 000 us] Allows you to set in increments of 10 us.

ff The adjustment range depends on the input signal.

[3D TEST MODE]

Set the image display system for use with 3D system adjustments.

1)Press as to select [3D TEST MODE].

2)Press qw to switch the item.

[NORMAL]

Standard setting.

[SIDE BY SIDE]

The left eye image is displayed on the left, next to the right eye image displayed on the right.

[LEFT/LEFT]

Both the left eye image and right eye image display the left eye input signal.

[RIGHT/RIGHT]

Both the left eye image and right eye image display the right eye input signal.

[LEFT/BLACK]

The left eye input signal is displayed in the left eye image and a completely black image is displayed

in the right eye image.

 

[BLACK/RIGHT]

A completely black image is displayed in the left eye image and the right input signal is displayed in

the right eye image.

 

Note

ff The [3D TEST MODE] settings return to [NORMAL] when the projector is switched off. ff This is disabled when [3D SYSTEM SETTING] is set to other than [SINGLE].

ff This is disabled when [3D TEST PATTERN] is displayed.

94 - ENGLISH