Standards Compliance for SNMP Traps

Enterprise-Specific Traps

EnterpriseSpecific traps indicates that an enterprise-specific event has occurred. The Specific-trap field identifies the particular trap that occurred. The following table lists the enterprise-specific traps supported by the unit:

SNMP Trap

Description

Possible Cause

 

 

 

enterprisePrimary

A failure of the currently

The configured clock source

ClockFail(1)

configured primary clock

is no longer operational. If

 

source for the unit has

the configured clock source

 

been detected.

is the internal clock, the

 

 

possible cause may be due

 

 

to a failure of one or more of

 

 

the units hardware

 

 

components.

 

 

 

enterpriseSecondary

A failure of the secondary

The configured clock source

ClockFail(4)

clock source for the unit

is no longer operational. If

 

has been detected.

the configured clock source

 

 

is the internal clock, the

 

 

possible cause may be due

 

 

to a failure of one or more of

 

 

the units hardware

 

 

components.

 

 

 

enterprisePrimary

Clock failure has cleared.

N/A

ClockFailClear(101)

 

 

 

 

 

enterpriseSecondary

Clock failure has cleared.

N/A

ClockFailClear(104)

 

 

 

 

 

enterpriseSelfTestFail(2)

A hardware failure of the

Failure of one or more of the

 

unit is detected during the

unit's hardware components.

 

unit's self-test. The trap is

 

 

generated after the unit

 

 

completes initialization.

 

 

 

 

enterpriseDeviceFail(3)

An internal device failure.

Operating software has

 

 

detected an internal device

 

 

failure.

 

 

 

enterpriseTestStart(5)

A test is running.

At least one test has been

 

 

started on an interface.

 

 

 

enterpriseConfig

The configuration changed

Configuration has been

Change(6)

via the user interface. The

changed via the ATI.

 

trap is sent after

 

 

60 seconds have elapsed

 

 

without another change.

 

 

This suppresses the

 

 

sending of numerous traps

 

 

when multiple changes are

 

 

made in a short period of

 

 

time, as is typically the

 

 

case when changing

 

 

configuration options.

 

 

 

 

enterpriseFallback

The LTU was unable to

The transmission quality of

AutoRate(13)

resynch to the last known

the DSL line has degraded

 

rate after a loss of signal.

since the LTU last synched

 

 

up.

 

 

 

7986-A2-GB20-00

September 1998

B-3

Page 103
Image 103
Paradyne HOTWIRE 7986 manual Enterprise-Specific Traps