Messages and Troubleshooting
Troubleshooting
This Model 7986 Standalone Termination Unit is designed to provide you with many years of
Table 6-2. Troubleshooting (1 of 2)
Symptom | Possible Cause | Solutions |
|
|
|
Alarm LED is on. | One of several alarm | Refer to Table |
| conditions exists. Health | Messages, for recommended action. |
| and Status displays the |
|
| alarm condition. |
|
|
|
|
Cannot access the unit via the ATI.
The terminal is not set up for the correct rate or data format, or the unit is configured so it prevents access.
HCheck the cable and connections.
HEnsure the unit is configured properly. Verify IP address and communication port usage.
HReset the unit.
Device Fail appears | The unit detects an internal | H Reset the unit. |
on the System and | hardware failure. | H Contact your service |
Test Status screen |
| |
| representative. | |
under |
| |
|
| |
results. |
|
|
|
|
|
No power, or the | The power cord is not | Check that the power cord is |
LEDs are not lit. | securely plugged into the | securely attached at both ends. |
| wall receptacle and into the |
|
| rear panel connection. |
|
|
|
|
| The wall receptacle has no | H Check the wall receptacle power |
| power. | by plugging in some equipment |
|
| that is known to be working. |
|
| H Check the circuit breaker. |
|
| H Verify that your site is not on an |
|
| energy management program. |
|
|
|
| Power supply has failed. | Replace power supply. |
|
|
|
An LED is not lit. | LED is out. | Run the Lamp test. If the LED in |
|
| question does not flash with the other |
|
| LEDs, then contact your service |
|
| representative. |
|
|
|
September 1998 |