Paradyne HOTWIRE 7986 manual Running Network Tests, Main Menu → Test → Network & G.703 Tests

Models: HOTWIRE 7986

1 122
Download 122 pages 29.23 Kb
Page 60
Image 60

Testing

Running Network Tests

Network tests require the participation of your network service provider. To access the Network Tests screen, follow this menu selection sequence:

Main Menu Test Network & G.703 Tests

main/test/network_G.703 Hotwire

 

 

Model: 7986

 

NETWORK & G.703 TESTS

Test

Command Status

Results

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±È±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Local Loopbacks

Line Loopback:

Start

Inactive

00:00:00

Repeater Loopback:

Start

Inactive

00:00:00

DTE Loopback:

Start

Inactive

00:00:00

Remote Loopbacks

 

 

 

Send Line Loopback: Down

Send

Inactive

00:00:00

Pattern Tests

 

 

 

Send and Monitor 511

Stop

Active

hh:mm:ss - Errors 99999+

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±È±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ResetMon

Use the Command column to start or stop a test. When the Status column shows that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed. Position the cursor at the desired Start or Stop command and press Enter.

Selecting a Stop command on the Network Tests screen or Abort All Tests from the Test menu will not disrupt a network-initiated loopback.

The Results column displays the test duration.

When the Send and Monitor 511 test is active, ResetMon is available to reset the error counter to zero.

5-2

September 1998

7986-A2-GB20-00

Page 60
Image 60
Paradyne HOTWIRE 7986 manual Running Network Tests, Main Menu → Test → Network & G.703 Tests