Monitoring the Unit

Table 4-1. Health and Status Messages (2 of 2)

Message

What Message Indicates

What To Do

 

 

 

Fallback Rate,

The LTU, set to AutoRate

Reset AutoRate.

Pt 1

enable, synchronized at a

AutoRate is designed to find the

 

lower rate when the line

 

best rate possible for your DSL loop

 

was restored after an LOS.

 

 

conditions. After the DSL loop is up

 

 

units should be run in fixed rate.

 

 

 

 

Primary Clock Failed

A failure has occurred in

1.

Verify that the network cable is

(G.703 Pt 1)

the primary clock source

 

securely attached at both ends.

 

configured from the

2.

Contact network provider.

 

Network, G.703, or from

 

 

 

 

the card internal clock.

 

 

 

 

 

 

DeviceFailed

An internal error has been

1.

Provide the 8-digit failure code

yyyyyyyy

detected by the operating

 

shown ( yyyyyyyy ) to your service

 

software. yyyyyyyy

 

representative.

 

indicates the 8-digit

2.

Reset the Model 7976

 

hexadecimal failure code.

 

 

Standalone Termination Unit to

 

 

 

 

 

 

clear the condition and message.

 

 

 

Download Failed

A firmware download was

Repeat the download.

 

interrupted.

 

 

 

 

 

 

Net Com Link Down

The Network

1.

Verify that the network cable is

 

communication link is

 

securely attached at both ends.

 

down. Communications

2.

Verify the link protocol for the

 

between the management

 

 

COM port is configured correctly.

 

system and the LTU/NTU

 

 

 

 

 

is not possible.

 

 

 

 

 

 

Mismatch Rate, Pt 1

The LTU, in fixed rate, is

1.

Verify endpoint is not a 1 Mbps

 

attempting to

 

product.

 

communicate at a faster

2.

Upgrade remote unit to a 2 Mbps

 

rate than the NTU can

 

 

or reconfigure the LTU for fixed

 

handle.

 

 

 

rate at a lower rate.

 

 

 

 

 

 

 

NTU TS16 Not

The LTU is configured for

1.

Verify endpoint is a G.703

Supported

TS16 signaling and the

 

product. EIA-530A products do

 

NTU is not configured to

 

not support signaling.

 

support TS16 signaling.

2.

Replace endpoint or reconfigure

 

 

 

 

 

TS16 to data.

 

 

 

 

4-4

September 1998

7986-A2-GB20-00

Page 48
Image 48