Monitoring the Unit
HStatus: Contains the contents of the status events register. The status events register maintains a history of specific events that have occurred during an interval. Values include:
ÐY ± Remote alarm indication signal received at the G.703 interface
ÐL ± Loss of signal detected at the G.703 interface
ÐE ± Excessive error rate threshold exceeded
ÐF ± Frame synchronization bit error detected
ÐV ± Line code violation detected
ÐNone ± No significant events have occurred
This Field . . . | Contains . . . |
|
|
Current interval | The number of seconds which have elapsed in the current |
timer | |
| This counter resets every 15 minutes. |
|
|
Payload Rate | The Payload Rate across the DSL interface. |
|
|
DSL Line Rate | The rate of the DSL line. The Line rate can be 144 kbps, |
| 272 kbps, 400 kbps, 528 kbps, 784 kbps, 1040 kbps, 1552 kbps, |
| or 2064 kbps. |
|
|
Current Interval | Performance data for the current 15 minutes. |
|
|
Interval xx | Historical performance data for up to 96 |
| (24 hours) where the value of xx is from 01 to 96. |
|
|
September 1998 |