Paradyne HOTWIRE 7986 manual Table A-2. G.703 Interface Options 2, Line Framing, Time Slot

Models: HOTWIRE 7986

1 122
Download 122 pages 29.23 Kb
Page 87
Image 87

Configuration Option Tables

Table A-2. G.703 Interface Options (2 of 2)

Line Framing

Possible Settings: CRC4, noCRC4

Default Setting: noCRC4

Specifies the framing format to be used by the G.703 interface.

CRC4 ± CRC4 framing formatting is used for transmitted and received data over the Network Interface.

noCRC4 ± Non-CRC4 framing format is used for transmitted and received data over the Network Interface.

Time Slot 16

Possible Settings: Signaling, Data

Default Setting: Signaling

Specifies weather the G.703 interface is used for voice or data.

Signaling ± Timeslot 16 is used for signalling (the unit is in voice mode).

Data ± Timeslot 16 is used for data (the unit is in data mode).

NOTE: For associated DSL line rates and payload rates refer to Table 3-4,Fixed Rate Payload Rates and DSL Line Rates in Chapter 3, Initial Startup and Configuration.

Primary Clock Source

Possible Settings: G.703, Internal

Default Setting: Internal

Specifies where the unit will derive its timing from.

Internal ± The clock source is derived from the internal oscillator.

G.703 Pt1 ± The clock source is derived from the G.703 interface.

Possible Settings: 1E±4, 1E±5, 1E±6, 1E±7, 1E±8, 1E±9

Default Setting: 1E±4

Determines the error rate at which an excessive error rate (EER) condition is recognized. The rate is the ratio of the number of CRC errors to the number of bits received in a certain period.

Send AIS on Network Failure

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies the action taken on the signal transmitted to the G.703 when a valid signal cannot be recovered from the network interface (LOS or cognitions OOF, AIS, or EER).

Enable ± An Alarm Indication Signal (AIS) is sent to the DTE in the event an LOS or continuous OOF, AIS, or EER condition exists on the G.703 interface.

Disable ± The failed signal on the interface is sent to the DTE in the event an LOS or continuous OOF, AIS, or EER condition exists on the G.703 interface.