0

5 – Managing Ports

 

 

Testing Ports

 

 

 

 

„Node-to-Node (Online) - The Node-to-Node test verifies communications between the port and its device node or device loop. The port being tested must be online and connected to a remote device. The port passes the test if the frame that was sent by the ASIC matches the frame that was received. This test does not disrupt communication on the selected port. This test requires that the port be online, and therefore, does not disrupt communication.

To run the internal, external, or online port loopback test on a port, do the following:

1.In the faceplate display, select the port to be tested.

2.Open the Port menu and select Port Loopback Test to open the Port Loopback Test dialog.

3.In the Test Selection area, click the radio button for the type of loopback test to be run (Internal, External, or Online). If you choose the internal or external test, SANsurfer Switch Manager will prompt you to confirm that the port state needs to be changed to the diagnostic state. Click the OK button and SANsurfer Switch Manager will change the port state.

4.Enter the frame count, frame size, and click a test pattern radio button. You may use the default pattern or enter an 8-digit pattern (hex). For online test, you can check the Terminate Test Upon Error check box if you want the test to stop should it encounter an error.

5.Click the Start Test button to begin the test. The Test Results area displays the test status, number of frames sent, and number of errors found.

6.To test another port, open the Select Port pull-down menu and select another port (number) and test type (Internal, External, or Online) in the Test Selection area.

7.Click the Start Test button to begin the next test. Observe the results in the Test Results area.

59056-02 A

5-17

Page 141
Image 141
Q-Logic 5202, 5200 manual Managing Ports