0 | 3 – Managing Fabrics |
| |
| Zoning a Fabric |
|
|
|
|
3.6.3.2.2
Default Visibility
Default visibility determines the level of communication that is permitted among ports/devices when there is no active zone set. The default visibility parameter can be set differently on each switch. When default visibility is enabled (ALL) on a switch, all ports/devices on the switch can communicate with all ports/devices on switches that also have default visibility enabled. When Default Visibility is disabled (NONE), none of the ports/devices on that switch can communicate with any other port/device in the fabric.
3.6.3.3
Saving the Zoning Database to a File
You can save the zoning database to an XML file. You can later reload this zoning database on the same switch or another switch. To save a zoning database to a file, do the following:
1.In the faceplate display, open the Zoning menu, and select Edit Zoning.
2.In the Edit Zoning dialog, open the File menu and select Save As.
3.In the Save dialog, enter a file name for the database file.
4.Click the Save button to save the zoning file.
3.6.3.4
Restoring the Zoning Database from a File
CAUTION! Restoring the zoning database from a file will replace the current zoning database on the switch.
Do the following to restore the zoning database from a file to a switch:
1.In the faceplate display, open the Zoning menu and select Edit Zoning to open the Edit Zoning window.
2.Open the File menu and select Open File. A popup window will prompt you to select an XML zoning database file.
3.Select a file and click Open.