Data set 1DT1

This is the message that actually performs data transmission, and is used when you wish to transmit the data.

Status

Data byte

Status

F0H

41H, dev, 00H, 43H, 12H, aaH, bbH,

F7H

 

ccH, ddH, eeH, ... ffH, sum

 

Byte

Explanation

 

F0H

Exclusive status

 

41H

ID number (Roland)

 

dev

Device ID (dev: 00H - 1FH, 7FH, Initial value is 10H)

00H

Model ID #1 (RD-700)

 

43H

Model ID #2 (RD-700)

 

12H

Command ID (DT1)

 

aaH

Address MSB: upper byte of the starting address of the data to be sent

bbH

Address: upper middle byte of the starting address of the data to be

 

sent

 

ccH

Address: lower middle byte of the starting address of the data to be

 

sent

 

ddH

Address LSB: lower byte of the starting address of the data to be sent.

eeH

Data: the actual data to be sent. Multiple bytes of data are transmitted

 

in order starting from the address.

 

:

:

 

ffH

Data

 

sum

Checksum

 

F7H

EOX (End Of Exclusive)

 

*The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. Refer to the address and size given in “Parameter Address Map” (p. 153).

*Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each packet will be sent at an interval of about 20 ms.

*Regarding the checksum, please refer to (p. 160)

*Not Received when the GM Mode is ON.

Data set 1DT1 (GM Mode)

Status

Data byte

Status

F0H

41H, dev, 42H, 12H, aaH, bbH, ccH,

F7H

 

ddH, ... eeH, sum

 

Byte

Explanation

 

F0H

Exclusive status

 

41H

ID number (Roland)

 

dev

Device ID (dev: 10H)

 

42H

Model ID (GS)

 

12H

Command ID (DT1)

 

aaH

Address MSB: upper byte of the starting address of the transmitted

 

data

 

bbH

Address: middle byte of the starting address of the transmitted data

ccH

Address LSB: lower byte of the starting address of the transmitted

 

data

 

ddH

Data: the actual data to be transmitted. Multiple bytes of data are

 

transmitted starting from the address.

:

:

 

eeH

Data

 

sum

Checksum

 

F7H

EOX (End Of Exclusive)

 

*The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. Refer to the address and size given in “Parameter Address Map” (p. 153).

*Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each packet will be sent at an interval of about 20 ms.

*Regarding the checksum, please refer to (p. 160)

*Not Received when the GM Mode is OFF.

MIDI Implementation

2. Data Transmission Channel Voice Messages Note off

Status

2nd byte

3rd byte

8nH

kkH

40H

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

 

00H - 7FH (0 - 127)

*Note off message is sent out with the velocity of 40H.

Note on

Status

2nd byte

3rd byte

9nH

kkH

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

 

00H - 7FH (0 - 127)

vv = note on velocity:

01H - 7FH (1 - 127)

Control Change

*By selecting a controller number that corresponds to the setting of parameters of controllers (Control Src, Foot Controller Assign), the RD-700 can transmit any control change message.

*These messages are not transmitted when MIDI Tx Parameter is OFF.

Bank Select (Controller number 0, 32)

Status

2nd byte

3rd byte

BnH

00H

mmH

BnH

20H

llH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm, ll = Bank number:

00 00H - 7F 7FH (bank.1 - bank.16384)

*When Rec Mode is ON (EDIT:Utility:Rec Setting:Rec Mode), these messages are transmitted when Tone is selected.

*These messages are transmitted when Bank Select parameter is Set on MIDI Tx Part.

*The Bank Select Numbers corresponding to SRX series should be referred to the SRX series owner’s manual.

Modulation (Controller number 1)

Status

2nd byte

3rd byte

BnH

01H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Modulation depth:

00H - 7FH (0 - 127)

*These messages are transmitted when Modulation lever is operated.

Portamento Time (Controller number 5)

Status

2nd byte

3rd byte

BnH

05H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Portamento Time:

00H - 7FH (0 - 127)

*These messages are transmitted when Portament Time is set in MIDI Tx Mode.

Data Entry (Controller number 6, 38)

Status

2nd byte

3rd byte

BnH

06H

mmH

BnH

26H

llH

n = MIDI channel number: 0H - FH (ch.1 - 16)

mm, ll = the value of the parameter specified by RPN/NRPN mm = MSB, ll = LSB

*These messages are transmitted when Bend Range value is set in MIDI Tx Mode.

Volume (Controller number 7)

Status

2nd byte

3rd byte

BnH

07H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Volume:

 

00H - 7FH (0 - 127)

* These messages are transmitted when PART VOLUME Slider is operated.

Appendices

 

 

 

151

Page 151
Image 151