Detailed Settings for Each Function ([EDIT])

Bulk Dump SETUP

 

 

Restoring saved settings to the RD-700

6

Press CURSOR [

].

 

 

When returning settings saved to an external sequencer back

 

 

to the RD-700, an Exclusive message is transmitted from the

 

A screen like the one shown below appears.

 

external sequencer, then the data is received by the RD-700.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

Be aware that when you restore SETUPs data to the RD-700,

 

 

 

 

 

 

the data in the RD-700 will be overwritten and lost.

 

 

 

 

 

 

1. Use a MIDI cable to connect the MIDI OUT connector of

 

 

 

 

 

 

 

the external sequencer to the MIDI IN connector of the

 

Parameter

 

Value

 

RD-700.

 

 

 

 

 

 

2. Set the device ID number to the same setting as when

 

 

 

 

 

 

From

Setup number for the first Setup to

 

you performed the bulk dump.

be transmitted.

 

 

 

 

 

 

 

 

 

 

 

 

 

To

 

 

Setup number for the last Setup to be

 

 

 

 

 

 

 

 

 

 

transmitted.

 

 

 

 

 

Setting the Device ID Number “Setting the Device ID

 

 

 

 

 

 

 

 

 

 

 

 

Determines whether the system set-

Number (Device ID)” (p. 71)

Send System

tings are to be transmitted (YES), or

3. Make sure that [EDIT] indicator is extinguished.

 

 

 

not (NO).

 

 

 

If the [EDIT] indicator is lit, press [EDIT] to turn the

 

 

 

 

 

 

 

indicator light off and put the RD-700 in normal

7.

Press CURSOR [

] / [

] and [INC/YES]/[DEC/

 

 

performance mode.

 

NO] to set the transmitted SETUPs.

4. Transmit (play back) the data from the external

 

 

 

 

 

 

8.

Press CURSOR [

].

 

 

 

sequencer.

 

 

5. After the transmitting is finished, the display will

 

A screen like the one shown below appears.

 

 

indicate “COMPLETED.”

fig.Editmenu2.eps_150

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

After playback of the Bulk Dump SETUP data, the RD-700

 

 

 

 

 

 

writes the data to the internal memory. Be sure never to turn

 

 

 

 

 

 

off the power while this data is being written (while “Now,

9. Put the external sequencer in record mode.

writing Bulk Dump Data. Keep on POWER!” is showing).

 

 

 

10. Press [INC/YES] to transmit the settings.

 

 

 

 

 

 

 

To cancel the Bulk Dump, press [DEC/NO].

For details on transmitting exclusive data, refer to the

 

owner’s manual for your sequencer.

 

A screen like the one shown below appears.

 

 

 

 

fig.Editmenu2.eps_150

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Play back the external sequencer at the same tempo you used

 

 

 

 

 

 

when performing the bulk dump. If you use a faster tempo,

 

 

 

 

 

 

the data may not be restored correctly.

NOTE

11.After the transmitting is finished, the display will

indicate “COMPLETED.”

Data cannot be received if the Device ID of the receiving

device differs from the Device ID used when Bulk Dump was

You are returned to the Edit screen.

carried out.

 

12. Stop the external sequencer.

NOTE

 

 

Exclusive messages cannot be received when set to GM

 

Mode (p. 98). Carry out the operation after first exiting GM

 

Mode.

Edit Mode

93

Page 93
Image 93
Roland RD-700 owner manual Number Device ID p