Error Messages/Other Messages

Error messages

Indication:

MIDI Buffer Full

Situation:

Due to an inordinate volume of MIDI

 

messages received, the RD-700 has failed to

 

process them properly.

Action:

Reduce the amount of MIDI messages to be

 

transmitted.

Indication:

MIDI Communication Error

Situation:

A problem has occurred with the MIDI cable

 

connections.

Action:

Check that MIDI cables are not broken or

 

pulled out.

Indication:

BULK DUMP: Receive Data Error

Situation:

A MIDI message was received incorrectly.

Action:

If the same error message is displayed

 

repeatedly, there is a problem with the MIDI

 

messages that are being transmitted to the RD-

 

700.

Indication:

BULK DUMP: Check Sum Error

Situation:

There is a problem with the System Exclusive

 

message’s Check Sum.

Action:

Check the value of the Check Sum.

Other Messages

Indication:

Now, Transmitting System Exclusive.

Situation:

Indicated when a Data Request message (RQ1)

 

is received.

Action:

The RD-700 outputs the requested data while

 

this message continues to be displayed.

Indication:

Now, writing Bulk Dump Data. Keep on

 

POWER!!

Situation:

Indicated when Bulk Dump data is being

 

received.

Action:

Once received, the data is written to the RD-

 

700’s internal memory; be absolutely sure not

 

to turn off the power until “COMPLETED”

 

appears in the display.

Indication:

Unavailable while in Rec Mode

Situation:

This is displayed when the [MIDI TX] button is

 

pressed with Rec Mode “ON.”

Action:

When Rec Mode is “ON,” you cannot change

 

the MIDI TX settings. To make changes to the

 

MIDI TX settings, set Rec Mode to “OFF” (p.

 

97).