Siemens KVM series 3-1621 manual Configuring network speed settings, Examples

Models: KVM series 3-1621

1 127
Download 127 pages 17.24 Kb
Page 52
Image 52

Computer terminal operations

A static IP address can be used to provide a user-defined IP address, netmask, and default gateway for the KVM s3-1621 and KVM s3-1641 appliances. Use a static IP address for ease of configuration.

DHCP is a protocol that automates the configuration of TCP/IP-enabled computers. When DHCP is selected, the IP Address, Netmask, and Default Gateway settings are automatically assigned to the KVM s3-1621 and KVM s3-1641 appliances and cannot be modified by a user. If you are using the DHCP option, configure the DHCP target device to provide an IP address to the KVM s3-1621 or KVM s3-1641 appliance and then skip step 5.

Select the remaining options from the Network configuration menu to finish the configuration of the KVM s3-1621 or KVM s3-1641 appliance with an IP address, netmask, default gateway, and ping response.

Type 0 (zero) and press Enter to return to the Console Main menu. The KVM s3- 1621 or KVM s3-1641 appliance will then reboot.

4.1.2Configuring network speed settings

When changing network speed and/or network duplex settings on a FSC Digital KVM switch, the following rules must be considered:

RULE: The settings of the FSC Digital KVM switch and the Network Switch port to which it is connected must be set to the EXACT same settings.

Examples:

If the FSC Digital KVM switch is set to Auto-Negotiate, then the Network Switch MUST be set to Auto-Negotiate both SPEED and DUPLEX.

If the FSC Digital KVM switch is set to 100MB - FULL duplex, then the Network Switch must be set to 100MB - FULL duplex.

If the FSC Digital KVM switch is set to 10MB - HALF duplex, then the Network Switch must be set to 10MB - HALF duplex.

RULE: If the FSC Digital KVM switch has been in use within the past hour and you have changed the network settings, ARP tables in the network may need refreshing/flushing before a new connection can be established with the FSC Digital KVM switch.

To refresh the ARP tables, do one of the following:

Wait about 10 minutes or so for the ARP tables to rebuild automatically. -OR-

Clear the ARP table entry in a FSC Client Viewer workstation and Ping the appli- ance at its IP address. This can be done from a DOS window with following

commands:

a.ARP -d 1.2.3.4 (Where 1.2.3.4 is the IP address of the FSC Digital KVM switch.)

b.PING 1.2.3.4 (Where 1.2.3.4 is the IP address of the FSC Digital KVM switch. If the PING is successful, the FSC Digital KVM switch is ready for operation.)

44

590-591-609B

Page 52
Image 52
Siemens KVM series 3-1621 Configuring network speed settings, Examples, To refresh the ARP tables, do one of the following