Functions

11.4 Watchdog (WD)

11.4Watchdog (WD)

Function

The watchdog monitors the program execution and reports a program crash to the user by means of various reactions.

The watchdog is idle when the PC is switched on or after a HW-RESET(cold restart), i.e., no reaction of the WD is triggered.

WD reactions

If the WD is not triggered again within the set time (by driver or SOM program), the following reactions are initiated:

Response

Option

WD acknowledgement

None

Trigger a PC reset

Configurable

SOM or DiagMonitor software is activated

None

WD monitor times (TWD)

The TWD are adjustable in increments of one second in a range from 3 to 255 seconds.

Note

If the watchdog time is changed after the watchdog was enabled (i.e., while the watchdog is running), the watchdog is retriggered!

SIMATIC Panel PC 877

11-5

Operating instructions, Release 07/2006, A5E00877780-01

Page 113
Image 113